FURUNO
SP - 1 E7251S01D
SPECIFICATIONS OF SATELLITE COMPASS
SC-50
1 GENERAL
1.1 Heading accuracy 0.5° RMS
1.2 Heading resolution 0.1°
1.3 Follow-up 45°/s rate-of-turn
1.4 Settling time 3 minutes
1.5 Position accuracy 10 m, or 5 m (DGPS), 95% of the time
1.6 Heading/Nav data output
Number of port AD-10 format specialty: 1 port
AD-10: 5 ports or IEC 61162-1/2: 10 ports (selected from menu)
IEC 61162 format is RS-485 level
Sentences ATT, GGA, GLL, GNS, HDM, HDT, HVE, ROT, THS, VBW, VDR,
VHW, VTG, ZDA
1.7 Log pulse output 1 port, contact signal
1.8 Heading alarm output 1 port, contact signal, 48V, 1A max.
1.9 Motion signal output Pitch:1 port, Roll: 1 port
1.10 External heading input 1 port: AD-10 or IEC61162-1/2 format (auto recognition)
AD-10 Backup heading
IEC 61162 Water tracking speed
Sentences HDG, HDM, HDT, VBW, VHW, VLW
1.11 External beacon input 1 port, RTCM SC-104 format (RS-232C level)
2 DISPLAY UNIT
2.1
Display type 4.5 inch monochrome LCD, 120 x 64 dots
2.2 Effective area 60 mm (H) x 95 mm (W)
2.3 Contrast 64 levels
2.4 Display mode Heading, Nav data, Steering, Compass rose, Rate of turn and
Speed modes
3 POWER SUPPLY
12-24 VDC: 1.2-0.5 A
4 ENVIRONMENTAL CONDITIONS
4.1 Ambient temperature
Display/ Processor unit -15°C to +55°C, designed for protected area
Antenna unit -25°C to +70°C, designed for exposed area
4.2 Relative humidity 93% at 40°C
4.3 Degree of protection
Antenna unit IPX6
Display unit IPX5
Processor unit IPX0
4.4 Vibration IEC 60945