9. To escape from the test, press the [Esc] key twice on the terminal unit. The test mode is
stopped and the message shown below appears to notify you that normal operation has
been restored.
CAUTION
INF: Distress/SSAS Buttons returned to NORMAL OPERATION.
<Press ESC key to continue>
Further, because the button remains pushed in ( ), the message “Please return the
SSAS button into OFF-STATE.” appears.
10. Push the button again to pop it out (
).
11. Close the button cover.
12. Press the [Esc] key three times to return to the standby display.
Note: If the button is left pushed in (
) when the terminal unit is turned on, the equipment
displays “Please return the SSAS button into OFF-STATE.” Push the button again to
turn off (
) the button.
FELCOM 16 (no PC)
1. Turn off the communication unit.
2. Push the button of the No. 1 SSAS to turn it on (
).
3. Turn on the communication unit.
4. 30 seconds later the POWER, LOGIN and TX LEDs on the communication unit start
flashing together if the button is judged to be ON.
Note: An SSAS test report is automatically transmitted 30 seconds after all LEDs start
flashing at step 4. If you do not need to send the test report, skip to step 7.
5. 30 seconds after LEDs start flashing the SSAS test report is sent once to the address
specified for the youngest SSAS report number (1-5). At this time the LEDs flash rapidly.
If transmission was successful the LEDs mentioned in step 4 flash slowly. If transmission
failed, only the ERROR LED flashes (rapidly).
6. Push the button of the No. 1 SSAS to turn it off (
). The LEDs light in order of POWER,
LOGIN, TX, POWER, LOGIN, TX.
7. Push the button of the No. 2 SSAS to turn it on (
).
8. 30 seconds later the POWER, LOGIN and TX LEDs on the communication unit start
flashing together if the button is judged to be ON.
Note: An SSAS test report is automatically transmitted 30 seconds after all LEDs start
flashing. If you do not need to send the test report, skip to step 10.
9. 30 seconds after the above-mentioned LEDs start flashing the SSAS test report is sent.
10. Push the button of the No. 2 SSAS to turn it off ( ).
Note: If there is a No.3 SSAS, test it by following steps 7-10.
11. Finally, turn the communication unit off and then on again.
Note 1: After completing the testing, be sure to turn off all SSAS units.
Note 2: The normal mode is automatically restored after 60 minutes elapses in the test
mode.