113
Linkage Menu
+(/,&237(5
$,53/$1(*/,'(5
ŏ5HWXUQWR/LQNDJH0HQX
ŏ6HQVRU,',WLVXQQHFHVVDU\ZKHQXVLQJHYHU\RQH
VHQVRURIVHYHUDONLQGVPD\VWLOOEHVXIÀFLHQW
ŏ7RXFKWKH>6HQVRU@EXWWRQLQWKH/LQNDJH 0HQXWRFDOOWKHVHWXS
VFUHHQVKRZQEHORZ
Assignable slot
*Altitude sensors, GPS sensors and other data sensor units may use multiple slots.
*The sensor which uses two or more slots has restriction in a start slot.
6HQVRU
9DULRXVWHOHPHWU\VHQVRUVVHWWLQJ
The telemetry sensor slot number and which sensor is
used in each slot can be changed in this screen.
Since the sensor in each slot is determined at initialization
and the same slot number is memorized even for sensors
sold separately, sensors can be used by simply connecting
them to S.BUS2. When customizing the sensors yourself,
perform the settings in this screen.
>:KDWLVDVORW"@
Servos are classified by CH, but VHQVRUV are
FODVVL¿HGLQXQLWVFDOOHG³VORW´. There are VORWV
from  to .
$OWLWXGHVHQVRUV*36VHQVRUV and other data
sensor units may use PXOWLSOHVORWV.
By the sensor which uses two or more slots,
the required number of slots is automatically
assigned by setting up a VWDUWVORW.
When 2 or more of the same kind of sensor
are used, the sensors themselves must allocate
unused slots and memorize that slot.
*Three slots of altitude sensor are used.
*Eight slots of GPS sensor are used.
Sensor
The required
number of slots
The number which can be used as a start slot Selling area
TEMP (SBS-01T, SBS-
01TE)
1 slot 1 31
Global
RPM (SBS-01RM,
SBS-01RO, SBS-
01RB)
1 slot 1 31
Airspeed (SBS-01TAS) 1 slot 1 31
Voltage (SBS-01V) 2 slots
1,2,3,4,5,6,8,9,10,11,12,13,14,16,17,18,19,
20,21,22,24,25,26,27,28,29,30
Altitude (SBS-01/02A) 3 slots
1,2,3,4,5,8,9,10,11,12,13,16,17,18,19,20,21,
24,25,26,27,28,29
Current (SBS-01C) 3 slots
1,2,3,4,5,8,9,10,11,12,13,16,17,18,19,20,21,
24,25,26,27,28,29
S.BUS2 Servo sensor
(SBS-01S)
6 slots
1,2,8,9,10,16,17,18,
24,25,26
GPS (SBS-01/02G) 8 slots 8,16,24
TEMP125-F1713 1 slot 1 31
Europe
VARIO-F1712 2 slots
1,2,3,4,5,6,8,9,10,11,12,13,14,16,17,18,19,
20,21,22,24,25,26,27,28,29,30
VARIO-F1672 2 slots
1,2,3,4,5,6,8,9,10,11,12,13,14,16,17,18,19,
20,21,22,24,25,26,27,28,29,30
CURR-F1678 3 slots
1,2,3,4,5,8,9,10,11,12,13,16,17,18,19,20,21,
24,25,26,27,28,29
GPS-F1675 8 slots 8,16,24
Kontronik ESC 8 slots 8,16,24
ROXXY 5 slots 1,2,8,9,10,16,17,18,24,25,26
JetCat V10 14 slots
1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16,17,
18
PowerBox 16 slots 8,16

Other manuals for FUTABA T32MZ

Related product manuals