5. Check the level with the dipstick
Spark plug
Remove the spark plug and clean it with a wire
brush after the engine has cooled down
sufficiently. Using a feeler gauge, set the gap to
0.75 mm (0.030"). Replace the spark plug, and be
careful not to overtighten it.
Air Filter
Disconnect the air filter cover. Replace the air filter when dirty to prevent objects from entering the air intake.
WARNING: Avoid skin contact with the
oil. Wash your hands thoroughly with
soap and water after changing the oil.
ATTENTION: Used oil is a hazardous
waste product. We recommend that you
take used oil to your local disposal center
for proper disposal. Do not dispose of
the device with household waste.