11
Minimum speed outtake:
Use this to have your ventilation system operating
all the time. This will keep the outtake fan running
and keep negative pressure in you room at all times,
to stop odours escaping your room.
Maximum speed Outtake:
To be used if noise is an issue. You can lower the
maximum speed and therefore the maximum noise.
Negative Pressure Intake:
This will set your intake fan speed below your
outtake fan. If you set it at -20% when the outtake
fan is at 50% the intake fan will be at 40%
(20 % of 50% = 10% reduction). This is to maintain
negative pressure in your grow room.
SETTING THE FAN SPEED
From the Fan Settings Menu (as detailed on page 9),
press DOWN and scroll down to ‘Fan settings.
With ‘Fan settingsblinking, press ENTER to access the
fan speed settings.
Use the UP and DOWN arrows to select your chosen
setting of Minimum speed, Maximum speed or
Negative pressure.
With your chosen selection blinking press ENTER to
highlight the corresponding value.
Use the UP and DOWN arrows to change the value.
Press SAVE EXIT to save your information, and to go
back to the previous sub menu.
DUMP OVERRIDE FUNCTION
Allows you to programme your fans to dump
the air out of your grow room. It takes your
outlet fan up to the maximum set fan speed,
and your inlet to the maximum fan speed, less
the set negative pressure.
The timer works on a 24 hour clock and you
can set 23 different times.
From the Fan Settings Menu (as detailed on page 9),
press DOWN and scroll down to ‘Dump Override’.
With ‘Dump Override’ blinking, press ENTER to access
the dump override settings.
Use the UP and DOWN arrows to select your chosen
setting from 1 to 23.
With your chosen selection blinking press ENTER to
highlight the corresponding ON TIME value.
Use the UP and DOWN arrows to change the value,
and press ENTER to highlight the next value.
Once you have your chosen ON TIME settings, press
ENTER to highlight the OFF TIME value. This shows
hours : mins : secs and can be changed in the same way.
Press SAVE EXIT to save your information. Press SAVE
EXIT again to go back to the previous sub menu.
Select Fan Settings as detailed on page 9
Press to change value
to access Fan Speed Settings
Press
ENTER
essing will save your entry and go back to the previous menu
SAVE
EXIT
Press
to scroll down to Fan settings
Dump Override
Fan settings
Set temperature
Set humidity
Minimum speed
Outtake 20%
Minimum speed
Outtake 20%
Maximum speed
Outtake 70%
Negativepressure
Intake -20%
to highlight the corresponding value
Press
ENTER
Press
to make your selection
DUMP OVERRIDE MENU
Select Fan Settings as detailed on page 9
to highlight the first value
Press
ENTER
ON TIME
hours : mins
OFF TIME
hours : mins : secs
to highlight the next value
Press
ENTER
Press
to make your selection from 1 to 23
Press to change value
to access Dump Override Settings
Press
ENTER
Pressing will save your entry.
SAVE
EXIT
Press again to go back to the previous menu
SAVE
EXIT
Press
to scroll down to Dump Override
Dump Override
Set fan Speed
Set temperature
Set humidity
Dump timer 1
0:00 00:00:00
Dump timer 1
0:00 00:00:00