HEAT SETTING
You can set the desired temperature of your room
when a heater is connected to Exit 1 or Exit 2.
The controller will turn on the heater whenever it is
below these values.
From the Set exit 1 or Set exit 2 Settings Menu (as detailed
on page 12), press DOWN and scroll down to ‘Heat’.
With ‘Heat’ blinking, press ENTER to access the heat settings.
Use the UP and DOWN arrows to select Heat Day, Heat
Night or Band width.
With your chosen selection blinking press ENTER to highlight
the corresponding value.
Use the UP and DOWN arrows to change the value.
Press SAVE EXIT to save your information, and to go back
to the previous sub menu.
HUMIDIFY SETTING
With a humidifier connected to Exit 1 or Exit 2:
From the Set exit 1 or Set exit 2 Settings Menu
(as detailed on page 12), press DOWN and scroll down
to ‘Humidify’.
With ‘Humidify’ blinking, press ENTER to access the
humidifier settings.
Use the UP and DOWN arrows to select Humidify
Day, Humidify Night or Band width.
With your chosen selection blinking press ENTER to
highlight the corresponding value.
Use the UP and DOWN arrows to change the value.
Press SAVE EXIT to save your information, and to go
back to the previous sub menu.
Humidify
Timer
Dehumidify
Heat
Power
Select Set exit 1 or Set exit 2 settings as detailed on page 12
to access Heat Settings
Press
ENTER
essing will save your entry and go back to the previous menu
SAVE
EXIT
Press
to scroll down to Heat
Exit1 Temp
Heat day 24.0°C
Heat Day 24.0°C
Heatnight 20.0°C
Band width -2°C
to highlight the corresponding value
Press
ENTER
Press
to make your selection
Press to change value
Humidify
Timer
Dehumidify
Heat
Power
Select Set exit 1 or Set exit 2 settings as detailed on page 12
to access Humidify Settings
Press
ENTER
essing will save your entry and go back to the previous menu
SAVE
EXIT
Press
to scroll down to Humidify
Exit1 Humidify
Humidify day 60%
Humidify day 60%
Humidi night 50%
Band width -5%
to highlight the corresponding value
Press
ENTER
Press
to make your selection
Press to change value
HEAT SETTING BAND WIDTH
The controller can be programmed to turn the heater on
whenever it drops below your set room temperature.
The band width is how many °C the temperature can
drop below the set room temperature before the heater
is turned back on. In the example to the right, during the
day the heater will turn off at 24°C and turn back on at
22°C (band width set to –2°C).
HUMIDIFY SETTING BAND WIDTH
The controller can be programmed to turn the humidifier
on whenever it drops below your set value.
The band width is how many % the humidity can drop
below the set humidity value before the humidifier is
turned back on. In the example to the right, during the
day the humidifier will turn on at 55% and turn back off
at 60% (band width set to –5%).