OPERATION OF AIR CONDITIONER
Unit Parameter modification
1113
13
When the unit is off, press SET button for 5 seconds until the beeper raises a Bi
sound, and then enter the right password and press SET button again to move
into unit parameter modify mode (The word PASS will show up).
Note: Contact the local dealer for the password.
At unit parameter modification mode, press TIME and TIME to select
the parameters to be changed; press UP and DOWN to change the
parameters; Press RESET button to restore all the parameters to factory setting.
04
05
06
07
Parameters
03
08
Normal range
Default value
Instructions
NOTICE
The parameter modification must be permitted by the manufacturer, otherwise the
manufacturer will not be responsible for any problems caused by the modification.
NO.
10
11
12
13
09
14
02
01
15
Coil over-heating protection in heating
Compressor minimum standby time
Compressor minimum running time
Defrosting time
Coil anti-freezing protection in cooling
Outdoor coil temp. to end defrosting
Fahrenheit or Celsius temperature
12 hours or 24 hours mode
Mode changing setting
Automatic restarting
Fan high speed shielding setting
Outdoor coil temp. compensation
Room temp. compensation
Light wave generator/Crankcase heater
Shielding time of low pressure protection
50 ~80
0~10 mins
0~10 mins
-5 ~15
0~10 mins
8~20 mins
0/1
0/1
0/1
8~20
0/1
0/1
0/1
-5 ~5
-5 ~5
65
3mins
3mins
-2
3mins
8mins
0
0
0
12
0
0
0
0
0
0: enable; 1: disable
0:Celsius; 1:Fahrenheit
0:24 hours; 1:12 hours
0:On standby or running state,
mode changing is available;
0:Three fan speeds ;
1: Shielded high speed
0:Light wave generator;
1:Crankcase heater
ā--ā means outdoor coil sensor
detection is shielded.
1:On running state, mode changing
is unavailable;
14