Gallagher 3E2375 Mains Energizer User Manual
14
ENERGIZER AND FENCE MAINTENANCE CHART
Plug into power outlet.
Test power point
Have Energizer repaired
Unplug the Energizer from the
power supply and remove the
fence wire from the Red terminal.
Plug Energizer in again. Using a
Digital Volt Meter (G5030) check
the voltage across the terminals.
If the voltage is less than 5000V,
have Energizer repaired.
Improve the ground system by
adding more galvanised ground
rods to the ground system unƟ l
the ground voltage is 200V or
below.
Check the electrical connecƟ ons
are secure e.g. from the fence to
the red terminal, from the ground
system to the green terminal, at
gates etc. Check the voltage on
the fence every 100Ō (33m) using
the Digital Volt Meter. Note if the
voltage is dropping. The closer
to a fault, the lower the voltage
reading will be. Become aware
of things that cause faults and
always be on the lookout for; stray
pieces of wire on the fence, heavy
vegetaƟ on growth, cracked or
broken insulators, broken wires.
For more detailed fencing instrucƟ ons refer to the Gallagher Power Fence Systems
Manual.
Save these instrucƟ ons
Fault Possible Cause(s) Solution
Energizer doesn’t operate
Electric fence voltage
is below 3000V or your
stock are escaping
Energizer Oī
Break in supply circuit
Faulty Energizer
Faulty Energizer
Inadequate grounding
Short on the fence line