Gallagher 3E5315 S6 Lithium Solar Fence Energizer User Manual
English
electried wires shall be constructed so as to ensure that these wires are posioned at a
minimum distance of 150 mm from the vercal plane of the non-electried wires. The barbed
wire and razor wire shall be earthed at regular intervals.
Follow the installaon instrucons regarding earthing.
A distance of at least 10 m shall be maintained between the energizer earth electrode and any
other earthing system connected parts such as the power supply system protecve earth or
the telecommunicaon system earth.
Connecng leads that are run inside buildings shall be eecvely insulated from the earthed
structural parts of the building. This may be achieved by using insulated high voltage cable.
Connecng leads that are run underground shall be run in conduit of insulang material or else
insulated high voltage lead-out cable shall be used. Care must be taken to avoid damage to the
connecng leads due to the eects of animal hooves or tractor wheels sinking into the ground.
Connecng leads shall not be installed in the same conduit as the mains supply wiring,
communicaon cables or data cables.
Connecng leads and electric animal fence wires shall not cross above overhead power or
communicaon lines.
Crossings with overhead power lines shall be avoided wherever possible. If such a crossing
cannot be avoided it shall be made underneath the power line and as nearly as possible at
right angles to it.
If connecng leads and electric animal fence wires are installed near an overhead power line,
the clearances shall not be less than those shown in the table below.


Clearance m
Less than or equal to 1 000
3
Greater than 1 000 and less than or equal to
33 000
4
Greater than 33 000
8
If connecng leads and electric animal fence wires are installed near an overhead power line,
their height above the ground shall not exceed 3 m.
This height applies either side of the orthogonal projecon of the outermost conductors of the
power line on the ground surface, for a distance of:
- 2 m for power lines operang at a nominal voltage not exceeding 1 000 V;
- 15 m for power lines operang at a nominal voltage exceeding 1 000 V.