© Copyright
Gallo Technologies
. All Right Reserved
-
9
-
0
615
1
5
V54RS
B.
Function Programming:
1
.
System must be in Disarm mode (
green
Start/Stop Engine
button
LED flashing).
2
.
Press valet switch 5 times, hold
on the 5
th
press
for over 5 seconds, parking lights will flash 2 times.
3
.
According to the Function Option Chart” below, you can set up the required function by pressing the Va
let
Switch the number of times indicated in Table 1
page 9
.
4
.
Immediately after pressing the valet switch the number of time indicated
,
press the
button on the key FOB. If
the parking lights flash 3 times, the default setting
for that function has been set. If the parking lights flash 1 time,
the alternate setting has been set.
Note: After entering the “Function Programming” mode, the
button must be pressed on the key FOB within 5
seconds. If
not, the system will exit the “Function Programming” mode and the parking lights will flash 4 times.
Repeat steps 1 thru 4 for each additional programming function.
Table 1: FUNCTION OPTION CHART
Press Valet
Switch # of
Times
Programmable
F
unction
Functi
on
Default
Lights flash 3 times
Function
Alternate
Light
s
flash 1 time
1
Remote start
Enable
Disable
2
Remote start run time
10 min
15 min
3
Gasoline/Diesel
Engine
Gasoline
Engine
Diesel
Engine
4
Ignition 2 output
Enable/Disable during
Engine start
Ig
nition 2 OFF during
Engine Start
Ignition 2 ON during
Engine Start
5
S
ilent arm/Disarm
ON
OFF
6
Foot
-
Brake
Door
lock/unlock
ON
OFF
7
Auto
Rea
rm
OFF
ON
8
Auxiliary output time
2
sec
duration
15 sec
duration
9
Aux output door unlock
Unlock Doors
Do no
t Unlock Doors
10
Electric siren/horn
Siren
Horn
11
Central
Door
lock
Time
(for 1 Pulse only)
0.
8
sec.
4sec
12
Door unlock Pulses
1 Pulses
2 Pulses(0.8sec*2)
13
Voltage/Tach Engine
running detection
Alternator
(
Voltage
)
Tach sensor
14
Return
all to
fa
ctory
default