CONTROL UNIT
User’s Manual
MODEL 500055
GAME READY CONTROL UNIT
MODEL 550350
PRE-PROGRAMMED CONTROL UNIT

Questions and Answers

  • H
    holly41Aug 17, 2025
    What to do if the Game ready 500055 Control Unit shows a Low Flow Alarm?
    • K
      Katherine CarrilloAug 17, 2025
      If the Game Ready Control Unit displays a Low Flow Alarm, check the hose and Wrap for any kinks that might be obstructing fluid flow. Ensure there is water in the ice box and that the ice box filter is clean. Also, reapply the Wrap, making sure it fits snugly against the body part being treated.
  • L
    Lisa BrownAug 20, 2025
    How to fix a Dry Pump Alarm on my Game Ready Control Unit?
    • R
      Rebecca SantosAug 20, 2025
      If your Game Ready Control Unit displays a Dry Pump Alarm, ensure there is water in the ice box and that the ice box filter isn't clogged. Try turning the Control Unit off and on again. You can also select “No Pressure” and run the system for one minute using the largest Wrap available.
  • L
    Leslie HillAug 22, 2025
    Why won't my Game ready 500055 Control Unit turn on?
    • U
      uwatersAug 22, 2025
      If your Game Ready system will not turn on, check that the AC adapter is securely plugged into a working electrical outlet.
  • J
    Jodi KimAug 26, 2025
    What to do if my Game ready 500055 Control Unit turns off during use?
    • A
      Andrew BarnesAug 26, 2025
      If the Game Ready Control Unit turns off during use, it may indicate a blockage in the fluid or air flow. Check the Wrap and the Connector Hose for any kinks, creases, or folds. Unplug the Control Unit to reset the system, and then try the Wrap again. If it shuts off again, try a different Wrap to determine if the issue is with the Control Unit or the Wrap.
  • J
    Jeffrey WrightAug 28, 2025
    How do I resolve an Over Pressure Alarm on my Game Ready Control Unit?
    • J
      Jocelyn WhiteAug 28, 2025
      If your Game Ready Control Unit shows an Over Pressure Alarm, turn the unit off and then back on. Also, try applying the same Wrap more tightly, or apply a different Wrap.
  • J
    John ButlerAug 30, 2025
    What does a Systems Error on the Game ready 500055 Control Unit mean?
    • A
      Ashley Wall MDAug 31, 2025
      A Systems Error on the Game Ready Control Unit indicates that the fluid pump may be working too hard, possibly due to ice or debris in the fluid circuit. Turn the Control Unit off and back on again. Check the filter. If that doesn't solve the problem, turn the Control Unit off for 20 minutes before turning it on again to try again.
  • V
    Victoria WilsonSep 2, 2025
    What should I do if my Game ready 500055 displays a 'Pressure Too High' alarm?
    • M
      mark98Sep 2, 2025
      If the Game Ready Control Unit displays a 'Pressure Too High' alarm, turn the unit off and back on. This error often occurs when the person being treated moves around during treatment and puts pressure on the air bladder. Try applying the same Wrap more tightly, or apply a different Wrap.
  • G
    Gary HowellSep 5, 2025
    What to do if my Game ready 500055 Control Unit displays a Low Flow Warning?
    • M
      Morgan PeckSep 5, 2025
      If the Game Ready Control Unit displays a Low Flow Warning, reapply the Wrap so that it is snug against the body part being treated.
  • A
    Adam ManningSep 8, 2025
    How to troubleshoot a Pressure Sensor Alarm on a Game ready 500055?
    • C
      chelseapaulSep 8, 2025
      If your Game Ready Control Unit shows a Pressure Sensor Alarm, disconnect the Wrap from the Control Unit. Turn the Control Unit off and on again without a Wrap connected.
  • D
    dsteeleSep 12, 2025
    Why can’t my Game Ready Control Unit reach its target maximum compression?
    • T
      Teresa CantuSep 12, 2025
      The Control Unit may not reach its target maximum compression due to a leak in the pneumatic compression circuit, either in the Connector Hose or the Wrap itself. Once treatment has finished, try the same pressure with a different Wrap, if one is available.

Summary

The Game Ready Difference

Indications for Use

Intended use of Game Ready System for cold and compression therapies for injuries.

Register Your Product

Instructions for registering the product to receive warranty service.

Contraindications for Use

Compression Therapy Contraindications

Patients for whom compression therapy should not be used.

Cryotherapy Contraindications

Patients for whom cryotherapy should not be used.

General Warnings and Precautions

General Safety Warnings

Warnings about tissue damage, skin monitoring, and wrap sterility.

Warnings for Specific Patient Groups

Warnings for patients with wounds, fractures, or specific conditions.

Operating Safety Warnings and Precautions

General Operating Warnings

Warnings about operating machinery, electrical shock, damaged cords.

General Handling Precautions

Precautions on water, hot water, handling the unit, and using wraps.

UL Safety Classification Information

Electric Shock Protection Details

Information on the power supply's protection against electric shock.

Water Ingress Protection Details

Details on the product's protection against water ingress.

Flammable Anesthetics;Oxygen Safety

Suitability for use in oxygen-enriched or flammable anesthetic environments.

System Mode of Operation

Recommended operating modes and rest periods for the system.

Electromagnetic Interference Compliance

Compliance with medical device limits for radio frequency energy.

Your Game Ready System Components

System Components Overview

Diagram and labels of the Game Ready System components.

Control Unit Placement Options

How to position the Control Unit for optimal use.

Control Panel and Basic Controls

Control Panel Interface Layout

Diagram and labels for the Control Unit's interface elements.

Wrap Priming Procedure

Step-by-step guide to filling a new Wrap or Cooling Vest with water.

Control Unit Setup Instructions

Filling the Ice Box

Instructions for filling the ice box with ice and water.

Refilling the Ice Box

How to refill the ice box to maintain cooling performance.

Connecting Wrap to Control Unit

How to properly connect the Wrap's connector hose to the Control Unit.

Wearing and Connecting Wraps

Warnings for Wrap Application

Warnings about incorrect use, tissue damage, and wrap sterility.

Connecting Hose to Wrap

Guidance on properly connecting the Connector Hose to the Wrap.

Important User Guidelines

Fluid Flow Management Tips

Ways to prevent fluid flow blockages and ensure proper operation.

Air Pressure Management Tips

How to avoid unintended pressure changes and system shutdowns.

Getting Started with Game Ready

Initial System Setup Steps

Step-by-step guide to prepare the system for use.

Selecting Treatment Programs

How to choose between standard, pre-programmed, and manual modes.

Control Panel Features Overview

Pressure Settings Explained

Explanation of different pressure levels (No pressure, Low, Medium, High).

Pre-Set Program Display Guide

Visual guide to pre-set program configurations.

Adjusting System Settings

Adjusting Compression Pressure

How to change the compression pressure level.

Adjusting Therapy Temperature

How to set the desired cold therapy temperature.

Setting Treatment Session Time

How to set the duration of the therapy session.

Continuous System Operation

Instructions for operating the system without a set timer.

Operating and Powering the System

System Operation within Carry Bag

How to use the system while it remains in its carrying case.

Powering the System with AC Adapter

Instructions for connecting and using the AC power adapter.

Care and Storage Instructions

Cleaning the Control Unit

How to clean the exterior and interior of the Control Unit.

Storage and Transportation

Recommended conditions for storing and transporting the system.

Cleaning and Replacing Filter

Steps for cleaning and replacing the system's filter.

Wrap Care and Storage

Cleaning Wrap Interior

Procedure for cleaning the Wrap's interior using hydrogen peroxide.

Wrap Storage Recommendations

Proper methods for storing Wraps to prevent damage and mold.

Bag Care and Storage

How to clean and store the carrying bag.

How to Pack the Game Ready System

Visual guide showing how to pack the system components into the bag.

Troubleshooting Common Issues

Soft Errors Explanation

Explanation of soft errors and how they affect system operation.

Hard Errors: Under Pressure;Low Flow

Troubleshooting steps for 'Under Pressure' and 'Low Flow' hard errors.

Hard Errors: Over Pressure;Pressure Too High

Troubleshooting steps for 'Over Pressure' and 'Pressure Too High' hard errors.

Advanced Troubleshooting

Hard Errors: Dry Pump;Pressure Sensor

Troubleshooting steps for 'Dry Pump' and 'Pressure Sensor' hard errors.

Hard Errors: Systems;Self-Test

Troubleshooting steps for 'Systems Error' and 'Self-Test Error'.

System Power-On Issues

Steps to diagnose why the system is not powering on.

Unit Shut-Off During Use

Reasons and solutions for the unit shutting off during operation.

Addressing Water Leakage

How to address water leakage issues when the unit is on its side.

Warranty Information

Control Unit Warranty Coverage

Details on the one-year limited warranty for the Control Unit.

Obtaining Warranty Service

Instructions on how to get warranty service and the RMA process.

Warranty Limitations and Exclusions

Specific limitations and exclusions to the warranty terms.

Limitations of Liability

Information regarding the company's liability for damages.

Completing Warranty Registration

Information needed for the warranty registration card.

User Replaceable Items and Specifications

User Replaceable Items

List of parts that can be ordered by calling customer service.

Power Supply Disclaimer

Advice on power quality and surge protection for the system.

Product Specifications: Physical and Performance

Physical size, weight, pressure, and power specifications.

How to Contact Us

Game Ready customer service contact details and website.

Game ready 500055 Specifications

Operating Environment IconOperating Environment
pressure level (min)5 mm Hg
pressure level (max)75 mm Hg
Power IconPower
AC power (voltage and frequency)120V/60 Hz or 240V/50 Hz
DC input (voltage and current)12V/2.5 A
Weight and Dimensions IconWeight and Dimensions
width400 mm
height132 mm
depth210 mm
weight (empty)8 lbs
weight (full of ice & water)18 lbs