13-8-621 Page 40
MAINTENANCE SCHEDULE (See Detail Notes above)
Maintenance Action
As Indicated by
AutoSentry
Controller
Every 8
Hours
Every
125
Hours
Every
1000
Hours
Every
4000
Hours
Every
Year
Check/Change Air Filter .....................................................
Change Oil Separator .......................................................
Check Reservoir Oil Level **..............................................
Check for Proper Load/Unload...........................................
Check Dirt Accumulation on Cooler ...................................
Change Oil Filter Element & Clean Oil Return Strainer .....
Change Compressor Lubricant (AEON 4000) * .................
Check Relief Valve.............................................................
Check Condition of Hoses..................................................
Check Operation of Condensate Removal Solenoid Valve
Change Inlet Valve Seals...................................................
* See “Oil Change Interval Chart”, Figure 5-3, page 26, for specific lubricant life.
** Must be checked when the compressor is stopped and the air/oil mixture is separated.