3
2. Specifications
Ranges: Autoranging
AC Voltage: 600 Volts
AC Current: 600 Amps
Resistance (Ohms): 200 Ohms
Accuracy: AC voltage +/- 1.5%
AC current +/- 2.0%
Resistance +/- 1.0%
Function/Range switch: 4 functions
4 positions
Sample Rate: 2 times / sec
Operation Temperature: 32
o
F - 104
o
F
(
0
o
C - 40
o
C
)
Storage Temperature: 14
o
F - 140
o
F
(
-10
o
C - 60
o
C
)
3
1
2
Digit LCD Display
Recessed Input Jacks: Negative (-) input jack for black test lead, positive
(+) input jack for red test lead.
Batteries: Two - "AAA"
Important:
Read this operators manual thoroughly before using this
meter. This manual is intended to provide basic information
regarding this meter and to describe common test
procedures which can be made with this unit. Many types of
appliance, machinery and other electrical circuit
measurements are not addressed in this manual and should
be handled by experienced service technicians.
Use extreme caution when using this
meter. Improper use of this meter can result in severe
damage to property, severe personal injury or death.
Follow all instructions and suggestions in this operators
manual as well as observing normal electrical safety
precautions. Do not use this meter if you are unfamiliar
with electrical circuits and proper test procedures.
!
WARNING
GCM-221 11/29/04 10:39 AM Page 4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GB Instruments GCM-221 and is the answer not in the manual?

GB Instruments GCM-221 Specifications

General IconGeneral
BrandGB Instruments
ModelGCM-221
CategoryMeasuring Instruments
LanguageEnglish