EasyManua.ls Logo

GE Interlogix NX-8 - Security NetworX System

GE Interlogix NX-8 - Security NetworX System
61 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 19
NOTE: To “null” a zone, program the zone in “Partition Select” as zero (0) in all partitions and do not
use end-of-line resistors.
L LOCATION 25 - ZONES 1-8 ZONE TYPE (8 segments, numerical data)
Location 25 contains the Zone Type for zones 1-8. Segment 1 is for zone 1, and Segment 8 is for zone 8.
Default Zone Types are found in the table on page 18. To customize a Zone Type, see page 33.
LOCATION 26 - PARTITION SELECT, ZONES 1-8 (8 segments, feature selection data)
Location 26 is used to select the partition(s) that zones 1 - 8 reside in. A zone may reside in any combination
of the 8 partitions. If a burglary zone resides in more than 1 partition, it will only be active when all
partitions it resides in are armed. A zone that resides in more than 1 partition will be reported to its
lowest partition number. Location 26 has 8 segments. Segment 1 corresponds to zone 1, and Segment 8
corresponds to zone 8.
Segments 1 - 8: 1 = Partition #1
2 = Partition #2
3 = Partition #3
4 = Partition #4
5 = Partition #5
6 = Partition #6
7 = Partition #7
8 = Partition #8
L LOCATION 27 - ZONES 9-16 ZONE TYPE (8 segments, numerical data)
Location 27 contains the Zone Type for zones 9 -16. Segment 1 is for zone 9, Segment 8 is for zone 16.
Default Zone Types are found in the table on page 18. To customize a Zone Type, see page 33.
LOCATION 28 - PARTITION SELECT, ZONES 9-16 (8 segments, feature selection data)
Location 28 is used to select the partition(s) that zones 9-16 reside in. A zone may reside in any combination
of the 8 partitions. If a burglary zone resides in more than 1 partition, it will only be active when all
partitions are armed. A zone that resides in more than 1 partition will be reported to its lowest
partition. Location 28 has 8 segments. Segment 1 corresponds to zone 9 and Segment 8 corresponds to
zone 16.
Segments 1 - 8: 1 = Partition #1
2 = Partition #2
3 = Partition #3
4 = Partition #4
5 = Partition #5
6 = Partition #6
7 = Partition #7
8 = Partition #8
L LOCATION 29 - ZONES 17-24 ZONE TYPE (8 segments, numerical data)
Location 29 contains the Zone Type for zones 17-24. Segment 1 is for zone 17, Segment 8 is for zone 24.
Default Zone Types are found in the table on page 18. To customize a Zone Type, see page 33.
LOCATION 30 - PARTITION SELECT, ZONES 17-24 (8 segments, feature selection data)
Location 30 is used to select the partition(s) that zones 17-24 reside in. A zone may reside in any
combination of the 8 partitions. If a burglary zone resides in more than 1 partition, it will only be active
when all partitions are armed. A zone that resides in more than 1 partition will be reported to its
lowest partition. Location 30 has 8 segments. Segment 1 corresponds to zone 17 and Segment 8
corresponds to zone 24.
Segments 1 - 8: 1 = Partition #1
2 = Partition #2
3 = Partition #3
4 = Partition #4
5 = Partition #5
6 = Partition #6
7 = Partition #7
8 = Partition #8