Location 44 contains the "Duress" code. This Location contains either 4 or 6 digits. If the 6-digit code option is
enabled in Location 41, THIS CODE MUST CONTAIN SIX (6) DIGITS. If the 6-digit option is not enabled in location
41, the last 2 digits will be ignored. If the duress code is programmed, it will work for all partitions.
LOCATION 45 - AUXILIARY OUTPUT 1-4 PARTITION SELECTION (4 segments, feature selection data)
Location 45 is used to select which partition(s) the events must occur in before the output will activate. Location 45
has 4 segments. Segment 1 corresponds to output 1, and Segment 4 corresponds to output 4.
Segment 1 Segment 2 Segment 3 Segment 4
(Auxiliary 1) (Auxiliary 2) (Auxiliary 3) (Auxiliary 4)
1= Partition #1 1= Partition #1 1= Partition #1 1= Partition #1
2= Partition #2 2= Partition #2 2= Partition #2 2= Partition #2
3= Partition #3 3= Partition #3 3= Partition #3 3= Partition #3
4= Partition #4 4= Partition #4 4= Partition #4 4= Partition #4
5= Partition #5 5= Partition #5 5= Partition #5 5= Partition #5
6= Partition #6 6= Partition #6 6= Partition #6 6= Partition #6
7= Partition #7 7= Partition #7 7= Partition #7 7= Partition #7
8= Partition #8 8= Partition #8 8= Partition #8 8= Partition #8
LOCATION 46 - AUXILIARY OUTPUT 1-4 SPECIAL TIMING (4 segments, feature selection data)
Location 46 contains special timing feature activation for the four auxiliary outputs. Segment 1 corresponds to output
1, Segment 4 corresponds to output 4.
Segments 1 - 4: 1 = On if output should be timed in minutes; Off if timed in seconds.
2 = On if output should latch; Off if output should be timed.
3 = On if output should stop timing upon code entry; Off if the output should continue to time
upon code entry.
4 = On if output should only activate between the closing and opening time in loc. 52 and 53.
5 = On if output should only activate between the opening and closing time in loc. 52 and 53.
6 = On if output should be inverted (0 volts going to 12 volts when activated).
7 = Reserved.
8 = Reserved.
LOCATION 47 - AUXILIARY OUTPUT #1, EVENT AND TIME (2 segments, numerical data)
Segment 1: Use the chart on page 24 to select the event that will activate Auxiliary Output 1.
Segment 2: Program the timing from 0-255 (minutes or seconds, depending on data programmed in Segment 1,
Location 46). Programming a "0" makes the output follow the event.
LOCATION 48 - AUXILIARY OUTPUT #2, EVENT AND TIME (2 segments, numerical data)
Segment 1: Use the chart on page 24 to select the event that will activate Auxiliary Output 2.
Segment 2: Program the timing from 0-255 (minutes or seconds, depending on data programmed in Segment 2,
Location 46). Programming a "0" makes the output follow the event.
LOCATION 49- AUXILIARY OUTPUT #3, EVENT AND TIME (2 segments, numerical data)
Segment 1: Use the chart on page 24 to select the event that will activate Auxiliary Output 3.
Segment 2: Program the timing from 0-255 (minutes or seconds, depending on data programmed in Segment 3,
Location 46). Programming a "0" makes the output follow the event.
LOCATION 50- AUXILIARY OUTPUT #4, EVENT AND TIME (2 segments, numerical data)
Segment 1: Use the chart on page 24 to select the event that will activate Auxiliary Output 4. .
Segment 2: Program the timing from 0-255 (minutes or seconds, depending on data programmed in Segment 4,
Location 46). Programming a "0" makes the output follow the event.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Interlogix NX-8 - Security NetworX System and is the answer not in the manual?

GE Interlogix NX-8 - Security NetworX System Specifications

Power IconPower
operating power16.5 VAC 25, 40, or 50 VA Transformer
auxiliary power with 25 VA transformer12 VDC Regulated 500 mA
auxiliary power with 40 or 50 VA transformer12 VDC Regulated 1 AMP
auxiliary power with NX-320 power supply12 VDC Regulated 2 AMPS + Control
Loop Specifications IconLoop Specifications
standard loop resistance300 Ohms Maximum
2-wire smokes resistance30 Ohms Maximum
loop responseSelectable 50mS or 500mS
Operating Environment IconOperating Environment
operating temperature32 to 120 degrees F
built-in siren driver2-tone (Temporal and Yelp)
LED keypad current draw130 mA max.
Weight and Dimensions IconWeight and Dimensions
metal enclosure dimensions11.25" Wide x 11.25" High x 3.50" Deep
shipping weight9 lbs.
LED keypad dimensions6.4" Wide x 4.0" High x 1.1" Deep
NX-148 LCD keypad dimensions6.4" Wide x 5.3" High x 1.0" Deep