L LOCATION 40 - SYSTEM TIMERS (10 segments, numerical data)
Location 40 contains the duration of various system timing functions. Example: If you desire the duration of the
Dynamic Battery Test to be 30 minutes, you should program [3]-[0]-[r] in segment 1 of this location. The [3]-[0] is the
number of minutes, and the [r] stores the data and moves to the next segment of this location.
Segment 1 - Dynamic Battery Test duration in minutes 0-255 minutes ("0" = no test)
Segment 2 - AC Fail report delay in minutes 0-255 minutes.
Segment 3 - Power Up Delay in seconds 0-60 seconds ("0" = no power up delay).
Segment 4 - Siren Time in minutes 1-255 minutes.
Segment 5 - Telephone Line Cut delay in seconds 0-255 seconds ("0" = no TLM).
Segment 6 - Cross Zone time in minutes 0-255 ("0" = no cross zoning).
Segment 7 - Chime time in 50 mS (1/20th second) increments from 0-12 seconds ("0" = follows zone 255 latched).
Segment 8 - Dial delay in seconds 0-255 seconds (ā€œ0 ā€ = no abort delay).
Segment 9 - Fire Alarm Verification time in seconds 120-255 seconds ("0" = no fire alarm verification). NOTE:
This feature is not approved for residential use in California
Segment 10 -Listen-In time in seconds 0-255 ("0" = no Listen-In time).
Note: The "Listen-In" feature cannot be enabled for UL Listed systems. The "Dynamic Battery Test" feature
cannot exceed four (4) hours. The dial delay shall be set to -0-.
LOCATION 41 - SPECIAL FEATURES (1 segment, feature selection data)
Segment 1:
1 - On enables the 6-digit code option. If 6-digit option is enabled, all arm/disarm codes and the "Go To
Program Code" are 6 digits. If this option is enabled, the default user 1 code is [1]-[2]-[3]-[4]-[5]-[6].
NOTE: IF YOU ENABLE THIS OPTION, VERIFY THAT THE "GO TO PROGRAM CODE" IS A SIX-
DIGIT CODE BEFORE EXITING PROGRAMMING.
2 - On requires code entry for [r]-[9]-[8] (perform call back download) and [r]-[9]-[9] (answer incoming call for
download) functions.
3 - Enable Auto Cancel / Abort (Refer to feature definitions beginning on page 3)
4 - Enable Walk-Test Mode (Refer to feature definitions beginning on page 3)
5-8 Reserved.
L LOCATION 42 - GO TO PROGRAM CODE (6 segments, numerical data)
Location 42 contains the "Go To Program Code". This location contains either a 4 or 6-digit code. If the 6-digit code
option is enabled in Location 41, THIS CODE MUST CONTAIN SIX (6) DIGITS. If this option is not enabled in
location 41, the last 2 segments (digits) will be ignored. With the NX-8 disarmed, the "Go To Program Code" can be
used to enter the Program Mode.
LOCATION 43 - GO TO PROGRAM CODE PARTITION AND AUTHORIZATION (2 segments, feature selection)
The "Go To Program Code" can be used as a standard arm/disarm code. When using the code to arm or disarm, the
user ID is 255. (This code may not be changed in the Run Mode.)
Segment 1: 1 - Reserved.
2 - On enables "Go To Program Code" as an arm only code.
3 - On enables "Go To Program Code" as an arm only after closing.
4 - On enables "Go To Program Code" as a master arm/disarm code (can change user codes)
5 - On enables "Go To Program Code" as an arm/disarm code.
6 - On enables "Go To Program Code" to bypass zones.
7 - On enables "Go To Program Code" opening and closing reports.
8 - Reserved.
Segment 2: 1 - On enables the "Go To Program Code" for Partition #1.
2 - On enables the "Go To Program Code" for Partition #2.
3 - On enables the "Go To Program Code" for Partition #3.
4 - On enables the "Go To Program Code" for Partition #4.
5 - On enables the "Go To Program Code" for Partition #5.
6 - On enables the "Go To Program Code" for Partition #6.
7 - On enables the "Go To Program Code" for Partition #7.
8 - On enables the "Go To Program Code" for Partition #8.
L LOCATION 44 - DURESS CODE (6 segments, numerical data)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Interlogix NX-8 - Security NetworX System and is the answer not in the manual?

GE Interlogix NX-8 - Security NetworX System Specifications

Power IconPower
operating power16.5 VAC 25, 40, or 50 VA Transformer
auxiliary power with 25 VA transformer12 VDC Regulated 500 mA
auxiliary power with 40 or 50 VA transformer12 VDC Regulated 1 AMP
auxiliary power with NX-320 power supply12 VDC Regulated 2 AMPS + Control
Loop Specifications IconLoop Specifications
standard loop resistance300 Ohms Maximum
2-wire smokes resistance30 Ohms Maximum
loop responseSelectable 50mS or 500mS
Operating Environment IconOperating Environment
operating temperature32 to 120 degrees F
built-in siren driver2-tone (Temporal and Yelp)
LED keypad current draw130 mA max.
Weight and Dimensions IconWeight and Dimensions
metal enclosure dimensions11.25" Wide x 11.25" High x 3.50" Deep
shipping weight9 lbs.
LED keypad dimensions6.4" Wide x 4.0" High x 1.1" Deep
NX-148 LCD keypad dimensions6.4" Wide x 5.3" High x 1.0" Deep