Do you have a question about the GE Interlogix NX-8 - Security NetworX System and is the answer not in the manual?
operating power | 16.5 VAC 25, 40, or 50 VA Transformer |
---|---|
auxiliary power with 25 VA transformer | 12 VDC Regulated 500 mA |
auxiliary power with 40 or 50 VA transformer | 12 VDC Regulated 1 AMP |
auxiliary power with NX-320 power supply | 12 VDC Regulated 2 AMPS + Control |
standard loop resistance | 300 Ohms Maximum |
---|---|
2-wire smokes resistance | 30 Ohms Maximum |
loop response | Selectable 50mS or 500mS |
operating temperature | 32 to 120 degrees F |
---|---|
built-in siren driver | 2-tone (Temporal and Yelp) |
LED keypad current draw | 130 mA max. |
metal enclosure dimensions | 11.25" Wide x 11.25" High x 3.50" Deep |
---|---|
shipping weight | 9 lbs. |
LED keypad dimensions | 6.4" Wide x 4.0" High x 1.1" Deep |
NX-148 LCD keypad dimensions | 6.4" Wide x 5.3" High x 1.0" Deep |
Controls alarm reporting delay and allows manual cancellation of reports.
Enables reporting of AC failure or low battery conditions to the central station.
Activates keypad sounder for AC power loss or low battery detection.
Manages user codes for system arming and disarming.
Allows the system to arm automatically at a specified time.
Automates the cancel and abort features without manual keypress.
Automatically bypasses interior zones or makes entry delay zones instant.
Schedules automatic communicator tests to the central station.
Configures four programmable outputs for relays, LEDs, etc.
Illuminates 'Service' LED for excessive current draw from system devices.
Enables reporting and sounding for tamper switch activation.
Features a built-in 112db siren driver.
Allows users to toggle zone bypass status with the [Bypass] key.
Enables a call back to the download computer before a download.
Sends a 'Cancel' report if system is disarmed within 5 minutes of an alarm.
Requires codes for zone bypassing and download initiation.
Supports various communication formats like Contact ID and SIA.
Requires multiple trips on a zone within a time frame before reporting an alarm.
Allows sending reports to multiple phone numbers by event or partition.
Sends a duress signal when the panel is armed/disarmed with a specific code.
Performs battery tests at specified intervals or upon arming/disarming.
Low-level arming mode for reducing false alarms with specific zone handling.
Reports an 'Exit Error' if an entry/exit zone is faulted at exit delay expiration.
Reports expander trouble and illuminates 'Service' LED.
Illuminates 'Service' LED if a report fails to reach the central station.
Verifies fire alarms by requiring multiple smoke detector trips.
Allows arming with violated zones which are then bypassed.
Reports ground faults or illuminates 'Service' LED.
Enables bypassing a designated group of zones prior to arming.
Sends alarm/restore reports immediately as they occur.
Stores up to 185 events with date and time.
Activates reports for Auxiliary 1 (Fire), Auxiliary 2 (Medical), and Keypad Panic.
Programs the keypad sounder to activate for specific events.
Disables keypad and reports tamper if invalid codes are entered.
Allows any zone to be programmed as a keyswitch zone for arm/disarm.
Turns off keypad LEDs (except Power) after 60 seconds of inactivity.
Disables programming from the keypad for specified locations.
Sends a report to the central station when the event log is full.
Illuminates 'Service' LED if the internal clock has an invalid time.
Allows performing bell/communicator tests via keypad commands.
Disables the eight on-board zones for a wireless system.
Allows partitioning the system into up to eight separate systems.
Sets the code used to enter programming mode.
One-button feature to arm the system using [Exit] or [Stay] keys.
Sends report if alarm occurs within 5 minutes of arming.
Restarts the exit delay by pressing the [Exit] key while armed.
Turns off keypad LEDs and disables keypresses.
Siren blast on arming, exit expiration, or closing acknowledgment.
Monitors siren circuit and reports wire cuts.
Silences exit delay by pressing [*]-[Exit] before arming.
Reports when programming or download sessions start and end.
Bypasses zones automatically after a specified number of alarms.
Monitors telephone line voltage and current for faults.
Affects fire siren behavior; not for UL installations.
Defeats answering machines with a single call and modem tones.
Defeats answering machines by requiring two calls.
Enables a walk-through zone test mode with audible feedback.
Reports wireless sensor issues and illuminates 'Service' LED.
Beeps keypad sounder upon arming if a zone is bypassed.
Allows using eight zones as sixteen normally closed zones.
Determines zone function and reporting based on 20 programmable types.
Sets the starting zone number for keypads.
Configures keypad features like sounder, LED behavior, and panics.
Assigns a unique number and partition to each keypad.
Sets elapsed increments for the last autotest.
Sets the current date for system operations.
Sets the current time for system operations.
Procedure for changing existing user codes.
Defines user permissions for system functions and partitions.
Describes the procedure to enter the system's programming mode.
Guides on selecting the specific module to program.
Details how to access and modify programming locations.
Explains how to save changes and exit a programming location.
Outlines the steps to exit the programming mode after changes.
Explains numerical and feature selection data types.
Describes how to input numerical data using keypad LEDs.
Programs the primary telephone number for reporting.
Sets the account code for the primary phone number.
Selects the communication format for Phone #1.
Configures dial attempts and backup control for Phone #1.
Selects which events are reported to Phone #1.
Selects which partitions' events are reported to Phone #1.
Programs the secondary telephone number for reporting.
Sets the account code for the secondary phone number.
Selects the communication format for Phone #2.
Configures dial attempts and backup control for Phone #2.
Selects which events are reported to Phone #2.
Selects which partitions' events are reported to Phone #2.
Programs the tertiary telephone number for reporting.
Sets the account code for the tertiary phone number.
Selects the communication format for Phone #3.
Configures dial attempts and backup control for Phone #3.
Selects which events are reported to Phone #3.
Selects which partitions' events are reported to Phone #3.
Allows creating custom communicator formats by overriding settings.
Sets the eight-digit access code for downloading.
Configures the number of rings before answering a download call.
Selects features for controlling download sessions.
Sets the number for call back after a download attempt.
Enables features and reports visible to users, configurable per partition.
Programs the entry and exit delay times for zones.
Sets the zone type for zones 1 through 8.
Assigns zones 1-8 to specific partitions.
Sets the zone type for zones 9 through 16.
Assigns zones 9-16 to specific partitions.
Sets the zone type for zones 17 through 24.
Assigns zones 17-24 to specific partitions.
Sets the zone type for zones 25 through 32.
Assigns zones 25-32 to specific partitions.
Sets the zone type for zones 33 through 40.
Assigns zones 33-40 to specific partitions.
Sets the zone type for zones 41 through 48.
Assigns zones 41-48 to specific partitions.
Enables various system features and reporting options.
Sets the trip count for zone bypassing after multiple alarms.
Configures keypad sounder activation for various events.
Configures system timing functions like battery test and dial delay.
Enables special system features like 6-digit codes and auto cancel.
Sets the primary code for entering the program mode.
Authorizes 'Go To Program' code for partitions and arm/disarm.
Sets a duress code that triggers silent alarms.
Selects partitions for auxiliary output activation.
Configures special timing features for auxiliary outputs.
Programs event and timing for Auxiliary Output 1.
Programs event and timing for Auxiliary Output 2.
Programs event and timing for Auxiliary Output 3.
Programs event and timing for Auxiliary Output 4.
Configures automatic system testing intervals and reporting.
Sets the time when 'arm only' codes can disarm the system.
Sets the time for auto-arming and disabling 'arm only' disarm capability.
Selects days partitions are open for 'arm only' disarming.
Selects days for automatic system arming.
Sets restore codes for slow speed formats.
Sets bypass codes for slow speed formats.
Sets tamper codes for slow speed formats.
Sets trouble codes for slow speed formats.
Sets low battery codes for slow speed formats.
Sets sensor missing codes for slow speed formats.
Worksheet for Duress codes.
Worksheet for Auxiliary 1 codes.
Worksheet for Auxiliary 2 codes.
Worksheet for Keypad Panic codes.
Worksheet for Keypad Tamper codes.
Worksheet for Box Tamper codes.
Worksheet for AC Fail codes.
Worksheet for Low Battery codes.
Worksheet for Power Short codes.
Worksheet for Bell Tamper codes.
Worksheet for Telephone Line Cut codes.
Worksheet for Ground Fault codes.
Worksheet for Expander Trouble codes.
Worksheet for Failure to Communicate codes.
Worksheet for Log Full codes.
Worksheet for Opening Codes.
Worksheet for Closing Codes.
Worksheet for Autotest codes.
Worksheet for Recent Closing and Exit Error codes.
Worksheet for Start/End Programming codes.
Worksheet for End Download codes.
Worksheet for Cancel codes.
Worksheet for Partition 1 Account Code.
Worksheet for Partition 2 Account Code.
Worksheet for Partition 2 Feature and Reporting Selection.
Worksheet for Partition 2 Entry/Exit Timers.
Worksheet for Partition 3 Account Code.
Worksheet for Partition 3 Feature and Reporting Selection.
Worksheet for Partition 3 Entry/Exit Timers.
Worksheet for Partition 4 Account Code.
Worksheet for Partition 4 Feature and Reporting Selection.
Worksheet for Partition 4 Entry/Exit Timers.
Worksheet for Partition 5 Account Code.
Worksheet for Partition 5 Feature and Reporting Selection.
Worksheet for Partition 5 Entry/Exit Timers.
Worksheet for Partition 6 Account Code.
Worksheet for Partition 6 Feature and Reporting Selection.
Worksheet for Partition 6 Entry/Exit Timers.
Worksheet for Partition 7 Account Code.
Worksheet for Partition 7 Feature and Reporting Selection.
Worksheet for Partition 7 Entry/Exit Timers.
Worksheet for Partition 8 Account Code.
Worksheet for Partition 8 Feature and Reporting Selection.
Worksheet for Partition 8 Entry/Exit Timers.
Worksheet for Zone Type 1 Alarm Event Code.
Worksheet for Zone Type 1 Characteristic Select.
Worksheet for Zone Type 2 Alarm Event Code.
Worksheet for Zone Type 2 Characteristic Select.
Worksheet for Zone Type 3 Alarm Event Code.
Worksheet for Zone Type 3 Characteristic Select.
Worksheet for Zone Type 4 Alarm Event Code.
Worksheet for Zone Type 4 Characteristic Select.
Worksheet for Zone Type 5 Alarm Event Code.
Worksheet for Zone Type 5 Characteristic Select.
Worksheet for Zone Type 6 Alarm Event Code.
Worksheet for Zone Type 6 Characteristic Select.
Worksheet for Zone Type 7 Alarm Event Code.
Worksheet for Zone Type 7 Characteristic Select.
Worksheet for Zone Type 8 Alarm Event Code.
Worksheet for Zone Type 8 Characteristic Select.
Worksheet for Zone Type 9 Alarm Event Code.
Worksheet for Zone Type 9 Characteristic Select.
Worksheet for Zone Type 10 Alarm Event Code.
Details the function of each terminal on the NX-8 panel.
Provides maximum wire run lengths for keypads.
Instructions for physically installing the circuit board within the enclosure.
Critical safety and procedural warnings for installers.