LOCATION 142 - ZONE TYPE 17 ALARM EVENT CODE (1 segment, numerical data)
Location 142 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen
from the list on page 52. The zone ID will be that zone that is in alarm. If 4+2 format is being used, the number
programmed in this location will be sent as the tens digit. When using 4+2, the digit in location 142 should be from 1-
15. The zone ID for 4+2 formats will be the ones digit of the zone that is in alarm.
LOCATION 143 - ZONE TYPE 17 CHARACTERISTIC SELECT (3 segments, feature selection data)
Use "Zone Type Characteristic Selections" described in Location 111, page 33.
LOCATION 144 - ZONE TYPE 18 ALARM EVENT CODE (1 segment, numerical data)
Location 144 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen
from the list on page 52. The zone ID will be that zone that is in alarm. If 4+2 format is being used, the number
programmed in this location will be sent as the tens digit. When using 4+2, the digit in location 144 should be from 1-
15. The zone ID for 4+2 formats will be the ones digit of the zone that is in alarm.
LOCATION 145 - ZONE TYPE 18 CHARACTERISTIC SELECT (3 segments, feature selection data)
Use "Zone Type Characteristic Selections" described in Location 111, page 33.
LOCATION 146 - ZONE TYPE 19 ALARM EVENT CODE (1 segment, numerical data)
Location 146 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen
from the list on page 52. The zone ID will be that zone that is in alarm. If 4+2 format is being used, the number
programmed in this location will be sent as the tens digit. When using 4+2, the digit in location 146 should be from 1-
15. The zone ID for 4+2 formats will be the ones digit of the zone that is in alarm.
LOCATION 147 - ZONE TYPE 19 CHARACTERISTIC SELECT (3 segments, feature selection data)
Use "Zone Type Characteristic Selections" described in Location 111, page 33.
LOCATION 148 - ZONE TYPE 20 ALARM EVENT CODE (1 segment, numerical data)
Location 148 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen
from the list on page 52. The zone ID will be that zone that is in alarm. If 4+2 format is being used, the number
programmed in this location will be sent as the tens digit. When using 4+2, the digit in location 148 should be from 1-
15. The zone ID for 4+2 formats will be the ones digit of the zone that is in alarm.
LOCATION 149 - ZONE TYPE 20 CHARACTERISTIC SELECT (3 segments, feature selection data)
Use "Zone Type Characteristic Selections" described in Location 111, page 33.