CHAPTER 12: 350 MODBUS MEMORY MAP AND FORMAT CODES 350 MODBUS MEMORY MAP
SR3 SERIES PROTECTIVE RELAY PLATFORM – COMMUNICATIONS GUIDE 12-43
44189 0x105C Sensitive Ground IOC 2 Shot
3 Initiate
0 1 1 --- FC103 0 1
44190 0x105D Sensitive Ground TOC Shot 3 0 1 1 --- FC103 0 1
44191 0x105E Block Negative Sequence
IOC Shot 3
0 1 1 --- FC103 0 1
AUTORECLOSE
42257 0x8D0 Initiate Reclosure 0 0xFFFF 1 --- F1 0 1
42259 0x8D2 Block Reclosure 0 0xFFFF 1 --- F1 0 1
44109 0x100C AR Function 0 1 1 --- FC126 0 1
44110 0x100D Number of Shots 1 4 1 --- F1 1 1
44111 0x100E Dead Time Shot 1 1 6000 1 s F2 10 1
44112 0x100F Dead Time Shot 2 1 6000 1 s F2 20 1
44113 0x1010 Dead Time Shot 3 1 6000 1 s F2 30 1
44114 0x1011 Dead Time Shot 4 1 6000 1 s F2 40 1
44115 0x1012 Reset Lockout Time 1 6000 1 s F2 100 1
44116 0x1013 Incomplete Sequence Time 1 6000 1 s F2 50 1
44117 0x1014 Reset Time 1 6000 1 s F2 50 1
44118 0x1015 Block AR 0 0xEF02 1 --- F89 0 1
44119 0x1016 External Initiate 0 0xEF02 1 --- F89 0 1
44120 0x1017 Phase IOC 1 Initiate 0 1 1 --- FC103 0 1
44121 0x1018 Phase IOC 2 Initiate 0 1 1 --- FC103 0 1
44122 0x1019 Neutral IOC 1 Initiate 0 1 1 --- FC103 0 1
44123 0x101A Neutral IOC 2 Initiate 0 1 1 --- FC103 0 1
44124 0x101B Ground IOC 1 Initiate 0 1 1 --- FC103 0 1
44125 0x101C Ground IOC 2 Initiate 0 1 1 --- FC103 0 1
44126 0x101D Phase TOC Initiate 0 1 1 --- FC103 0 1
44127 0x101E Neutral TOC Initiate 0 1 1 --- FC103 0 1
44128 0x101F Ground TOC Initiate 0 1 1 --- FC103 0 1
44129 0x1020 AR Ready Relays 0 0x7F 1 --- FC198 0 1
44130 0x1021 AR In-Progress Relays 0 0x7F 1 --- FC198 0 1
44131 0x1022 AR N/Ready Relays 0 0x7F 1 --- FC198 0 1
44132 0x1023 Select Setting Group -1 1 1 --- F91 0 1
44133 0x1024 Sensitive Ground IOC 1
Initiate
0 1 1 --- FC103 0 1
44134 0x1025 Sensitive Ground IOC 2
Initiate
0 1 1 --- FC103 0 1
44135 0x1026 Sensitive Ground TOC
Initiate
0 1 1 --- FC103 0 1
44136 0x1027 Negative Sequence IOC
Initiate
0 1 1 --- FC103 0 1
44137 0x1028 Negative Sequence TOC
Initiate
0 1 1 --- FC103 0 1
44152 0x1037 Negative Sequence TOC
Shot 1
0 1 1 --- FC103 0 1
44172 0x104B Negative Sequence TOC
Shot 2
0 1 1 --- FC103 0 1
44192 0x105F Negative Sequence TOC
Shot 3
0 1 1 --- FC103 0 1
44197 0x1064 Negative Sequence TOC
Shot 4
0 1 1 --- FC103 0 1
Modbus
Address
Hex
Address
Description Min Max Step Units Format
Code
Factory
Default
Size in
words