EasyManua.ls Logo

GE 750 - Page 56

GE 750
102 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4 - 36 750/760 FEEDER MANAGEMENT RELAY – COMMUNICATIONS GUIDE
MEMORY MAP CHAPTER 4: MODBUS MEMORY MAP
18AC
1
Analog Threshold 2 Pickup Type --- --- F85 Over
18AD Analog Threshold 2 Dropout Ratio 2 to 20 % F1 5%
ANALOG INPUT RATE 1 (read/write setpoints)
18B0 Analog In Rate 1 Function --- --- F38 Disabled
18B1 Analog In Rate 1 Relays --- --- F57 None
18B2 Analog In Rate 1 Pickup –1000.0 to 1000.0 Units / hr. F5 10.0 µA/hr.
18B3 Analog In Rate 1 Delay 0 to 60000 s F1 0 s
ANALOG INPUT RATE 2 (read/write setpoints)
18B8 Analog In Rate 2 Function --- --- F38 Disabled
18B9 Analog In Rate 2 Relays --- --- F57 None
18BA Analog In Rate 2 Pickup –1000.0 to 1000.0 Units / hr. F5 10.0 µA/hr.
18BB Analog In Rate 2 Delay 0 to 60000 s F1 0 s
ANALOG OUTPUT 1 (read/write setpoints)
18C0 Analog Output 1 Parameter --- --- F77 Disabled
18C1 Analog Output 1 Minimum --- --- F78 0
18C2 Analog Output 1 Maximum --- --- F78 0
ANALOG OUTPUT 2 (read/write setpoints)
18C4 Analog Output 2 Parameter --- --- F77 Disabled
18C5 Analog Output 2 Minimum --- --- F78 0
18C6 Analog Output 2 Maximum --- --- F78 0
ANALOG OUTPUT 3 (read/write setpoints)
18C8 Analog Output 3 Parameter --- --- F77 Disabled
18C9 Analog Output 3 Minimum --- --- F78 0
18CA Analog Output 3 Maximum --- --- F78 0
ANALOG OUTPUT 4 (read/write setpoints)
18CC Analog Output 4 Parameter --- --- F77 Disabled
18CD Analog Output 4 Minimum --- --- F78 0
18CE Analog Output 4 Maximum --- --- F78 0
ANALOG OUTPUT 5 (read/write setpoints)
18D0 Analog Output 5 Parameter --- --- F77 Disabled
18D1 Analog Output 5 Minimum --- --- F78 0
18D2 Analog Output 5 Maximum --- --- F78 0
ANALOG OUTPUT 6 (read/write setpoints)
18D4 Analog Output 6 Parameter --- --- F77 Disabled
18D5 Analog Output 6 Minimum --- --- F78 0
18D6 Analog Output 6 Maximum --- --- F78 0
ANALOG OUTPUT 7 (read/write setpoints)
18D8 Analog Output 7 Parameter --- --- F77 Disabled
18D9 Analog Output 7 Minimum --- --- F78 0
18DA Analog Output 7 Maximum --- --- F78 0
ANALOG OUTPUT 8 (read/write setpoints)
18DC Analog Output 8 Parameter --- --- F77 Disabled
18DD Analog Output 8 Minimum --- --- F78 0
18DE Analog Output 8 Maximum --- --- F78 0
OVERFREQUENCY (read/write setpoints)
18E0 Overfrequency Function --- --- F38 Disabled
18E1 Overfrequency Relays --- --- F57 None
18E2 Overfrequency Pickup 20.00 to 65.00 Hz F3 60.50 Hz
18E3 Overfrequency Delay 0.0 to 6000.0 s F2 5.0 s
TRIP COUNTER (read/write setpoints)
1900 Trip Counter Function --- --- F38 Disabled
1901 Trip Counter Relays --- --- F57 None
Table 3: Modbus Memory Map (Sheet 31 of 40)
ADDR DESCRIPTION RANGE UNITS TYPE DEFAULT
1 2 3 4 5 6 7 8 9 10 11 12 13