2.3.6 DC Link Reactor
Dimensions in inches
Terminal
Width
Depth
Height
Note:
AF-300 P11 Drives rated 100 Hp and above are furnished with a DC link reactor. This reactor must be installed
between terminal P1 and P+ prior to commissioning of the Drive.
The weight of the DC Link Reactor is not included with that of the Drive.
DC Link Reactor is provided as open type and is separately mounted. Enclosure to be provided by others.
Hp
Model No. Width Depth Height Weight Loss [W]
230V P11
100 DCR2-75B 7.87 10.63 7.09 37 55
125 DCR2-90B 7.09 11.02 8.46 37 57
150 DCR2-110B 7.48 12.99 9.05 46 67
460V P11
100 DCR4-75B 7.48 10.63 6.89 35 58
125 DCR4-90B 7.48 11.02 7.87 44 64
150 DCR4-110B 7.48 11.02 7.87 46 73
200 DCR4-132B 7.87 11.02 8.07 55 84
250 DCR4-160B 8.27 12.6 8.07 68 90
300 DCR4-200B 8.27 12.99 9.06 75 126
350 DCR4-220B 8.66 13.78 9.06 81 131
400 DCR4-280B 8.66 14.57 9.65 95 133
450 DCR4-280B 8.66 14.57 9.65 95 150
500 DCR4-355B 9.84 12.99 8.78 99 205
600 DCR4-400B 9.84 13.78 9.17 106 215
700 DCR4-450B 10.63 13.78 10.35 121 272
800 DCR4-500B 11.1 14.17 10.35 143 292