EasyManua.ls Logo

GE AF-300 P11 - Alphabetical Function List

GE AF-300 P11
154 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-5
5.2 Alphabetical Function List
PG. NAME
5-16 30RY operation mode F36 30RY MODE
5-10 Acceleration time 1 F07 ACC TIME1
5-22 Acceleration time 2 E10 ACC TIME2
5-22 Acceleration time 3 E12 ACC TIME3
5-22 Acceleration time 4 E14 ACC TIME4
5-34 ACC/DEC Pattern H07 ACC PTN
5-37 Active Drive H19 AUT RED
5-31 Analog setting signal filter C33 REF FILTER
5-10 Base frequency 1 F04 BASE Hz-1
5-44 Base frequency 2 A02 BASE Hz-2
5-14 Bias frequency F18 FREQ BIAS
5-34 Data initializing H03 DATA INIT
5-7 Data protection F00 DATA PRTC
5-14 DC brake (Braking level) F21 DC BRK LVL
5-14 DC brake (Braking time) F22 DC BRK t
5-14 DC brake (Starting freq.) F20 DC BRK Hz
5-36 DEC mode H11 DEC MODE
5-10 Deceleration time 1 F08 DEC TIME1
5-22 Deceleration time 2 E11 DEC TIME2
5-22 Deceleration time 3 E13 DEC TIME3
5-22 Deceleration time 4 E15 DEC TIME4
5-26 Display coefficient A E40 COEF A
5-26 Display coefficient B E41 COEF B
5-11 Electronic Thermal 1 (Level) F11 OL LEVEL1
5-11 Electronic Thermal 1 (Select) F10 ELCTRN OL1
5-11 Electronic Thermal 1 (Thermal
time constant)
F12 TIME CNST1
5-44 Electronic thermal 2 (Level) A07 OL LEVEL2
5-44 Electronic thermal 2 (Select) A06 ELCTRN OL2
5-44 Electronic thermal 2 (Thermal
time constant)
A08 TIME CNST2
5-11 Electronic thermal overload
rela
y
(for DB resistor)
F13 DBR OL
5-36 Energy-saving operation H10 ENERGY SAV
5-34 Fan stop operation H06 FAN STOP
5-25 FAR function (Hysteresis) E30 FAR HYSTR
5-25 FDT function (Level) E31 FDT1 LEVEL
5-25 FDT signal (Hysteresis) E32 FDT1 HYSTR
5-25 FDT2 function (Level) E36 FDT2 LEVEL
5-15 FMA (Voltage adjust) F30 FMA V-ADJ
5-15 FMA (Function) F31 FMA FUNC
5-16 FMP (Function) F35 FMP FUNC
5-16 FMP (Pulse rate) F33 FMP PULSES
5-16 FMP (Voltage adjust) F34 FMP V-ADJ
5-7 Frequency command 1 F01 FREQ CMD 1
5-30 Frequency command 2 C30 FREQ CMD 2
5-14 Frequency limiter (High) F15 H LIMITER
5-14 Frequency limiter (Low) F16 L LIMITER
5-14 Gain (for freq set signal) F17 FREQ GAIN
5-36 Instantaneous OC limiting H12 INST CL
5-29 JOG frequency C20 JOG Hz
5-28 Jump frequency (Hysteresis) C04 JUMP HYSTR
5-28 Jump frequency (Jump freq 1) C01 JUMP Hz 1
5-28 Jump frequency (Jump freq 2) C02 JUMP Hz 2
5-28 Jump frequency (Jump freq 3) C03 JUMP Hz 3
5-27 LCD Monitor (Contrast) E47 CONTRAST
5-27 LCD Monitor (Function) E45 LCD MNTR
5-27 LCD Monitor (Language) E46 LANGUAGE
5-26 LED Display filter E42 DISPLAY FL
5-26 LED Monitor (Function) E43 LED MNTR
LCD Display
PG. NAME
5-26 LED Monitor (Display @ STOP
mode)
E44 LED MNTR2
5-10 Maximum frequency 1 F03 MAX Hz-1
5-44 Maximum frequency 2 A01 MAX Hz-2
5-10 Maximum voltage 1 F06 MAX V-1
5-44 Maximum voltage 2 A04 MAX V-2
5-42 Modbus-RTU (Address) H31 ADDRESS
5-42 Modbus-RTU (Baud rate) H34 BAUD RATE
5-42 Modbus-RTU (Data length) H35 LENGTH
5-42 Modbus-RTU (Mode select on
no res
p
onse error)
H32 MODE ON ER
5-43 Modbus-RTU (No response
error detection time)
H38 NO RES t
5-42 Modbus-RTU (Parity check) H36 PARITY
5-43 Modbus-RTU (Response
interval)
H39 INTERVAL
5-42 Modbus-RTU (Stop bits) H37 STOP BITS
5-42 Modbus-RTU (Timer) H33 TIMER
5-33 Motor 1 (%R1 setting) P07 M1-%R1
5-33 Motor 1 (%X setting) P08 M1-%X
5-32 Motor 1 (Capacity) P02 M1 -CAP
5-33 Motor 1 (No-load current) P06 M1-lo
5-33 Motor 1 (On-line Tuning) P05 M1 TUN2
5-32 Motor 1 (Rated current) P03 M1-lr
5-32 Motor 1 (Tuning) P04 M1 TUN1
5-45 Motor 2 (%R1 setting) A16 M2-%R1
5-45 Motor 2 (%X setting) A17 M2-%X
5-44 Motor 2 (Capacity) A11 M2-CAP
5-45 Motor 2 (No-load current) A15 M2-Io
5-45 Motor 2 (On-line Tuning) A14 M2 TUN2
5-44 Motor 2 (Rated current) A12 M2-Ir
5-45 Motor 2 (Slip compensation
control 2)
A18 SLIP COMP2
5-45 Motor 2 (Tuning) A13 M2 TUN1
5-15 Motor sound (Carrier freq.) F26 MTR SOUND
5-15 Motor sound (Sound tone) F27 SOUND TONE
5-28 Multistep frequency setting
(Fre
q
. 1)
C05 MULTI Hz-1
5-28 Multistep frequency setting
(Fre
q
. 2)
C06 MULTI Hz-2
5-28 Multistep frequency setting
(Fre
q
. 3)
C07 MULTI Hz-3
5-28 Multistep frequency setting
(Fre
q
. 4)
C08 MULTI Hz-4
5-28 Multistep frequency setting
(Fre
q
. 5)
C09 MULTI Hz-5
5-28 Multistep frequency setting
(Fre
q
. 6)
C10 MULTI Hz-6
5-28 Multistep frequency setting
(Fre
q
. 7)
C11 MULTI Hz-7
5-28 Multistep frequency setting
(Fre
q
. 8)
C12 MULTI Hz-8
5-28 Multistep frequency setting
(Fre
q
. 9)
C13 MULTI Hz-9
5-28 Multistep frequency setting
(Fre
q
.10)
C14 MULTI Hz-10
5-28 Multistep frequency setting
(Fre
q
.11)
C15 MULTI Hz-11
5-28 Multistep frequency setting
(Fre
q
.12)
C16 MULTI Hz-12
5-28 Multistep frequency setting
(Fre
q
.13)
C17 MULTI Hz-13
5-28 Multistep frequency setting
(Fre
q
.14)
C18 MULTI Hz-14
5-28 Multistep frequency setting
(Fre
q
.15)
C19 MULTI Hz-15
LCD Display

Table of Contents

Related product manuals