5-1
5. Function Selection
5.1 Function Selection List
F: Fundamental Functions
Func.
Unit
Min.
Factory Setting Data Change
No.
30 HP 40 HP
Formst during op
F00
Data protection
F00 DATA PRTC
0, 1
-- 0
1N
F01
Frequency command 1 F01
FREQ CMD 1 0 to 11
-- 0
1N
F02
Operation method
F02
OPR METHOD 0 to 4
-- 0
1N
F03 Maximum frequency 1
F03
MAX Hz-1 50 to 120Hz
Hz 1 60
1N
F04
Base frequency 1 F04
BASE Hz-1 25 to 120Hz
Hz 1 60
1N
F05
Rated voltage 1
F05
RATED V-1
0V: (Output voltage
V1230: (230V class)
1
(at Base frequency 1)
proportional to source voltage)
460: (460V class)
230V class: 80 to 240V
460V class: 320 to 480V
F06 Maximum voltage 1
F06
MAX V-1
230V class: 80 to 240V
V1230: (230V class)
1
(at Maximum frequency 1) 460V class: 320 to 480V
460: (460V class)
F07 Acceleration time 1
F07
ACC TIME1 0.01 to 3600 s
s0.01
6.0
20.0
12
F08 Deceleration time 1
F08
DEC TIME1
F09 Torque boost 1
F09
TRQ BOOST1 0.0, 0.1 to 20.0
-0.1 2.0
12 Y
F10 Electronic (Select)
F10
ELCTRN OL1
0, 1, 2
-- 1
3Y
F11
Thermal 1
(level)
F11
OL LEVEL1
20 to 135% of drive rated current
A0.01
Motor rated current 1 Y
F12 (time constant)
F12
TIME CNST1
0.5 to 75.0 min min 0.1 5.0
10.0
19 Y
F13
Electronic thermal overload F13
DBR OL [ Up to 15 HP ]
--
3
relay (for braking resistor)
0, 1, 2
1
[ 20 HP and above ]
0
F14
Restart mode after
F14
RESTART
0 to 5
--
1
momentary power failure
F15 Frequency (high)
F15
H LIMITER 0 to 120 Hz
Hz 1 70
1Y
F16 Limiter (low)
F16
L LIMITER
0
1N
F17 Gain (for frequency set signal)
F17
FREQ GAIN
0.0 to 200.0%
%0.1 100.0
1Y
F18 Bias frequency
F18
FREQ BIAS -120.0 to +120.0 Hz
Hz 0.1 0.0
1Y
F20
DC brake (starting frequency)
F20
DC BRK Hz 0.0 to 60.0 Hz
Hz 0.1 0.0
3
F21
(braking level)
F21
DC BRK LVL 0 to 80% % 1 0 1
F22
(braking time)
F22
DC BRK t 0.0s (inactive) s 0.1 0.0 3
F23
Starting frequency
F23
START Hz 0.1 to 60.0 Hz Hz 0.1 0.5 3
F24
(holding time)
F24
HOLDING t 0.0 to 10.0 s s 0.1 0.0 3
F25
Stop frequency
F25
STOP Hz 0.1 to 6.0 Hz Hz 0.1 0.2 1
F26
Motor sound (carrier freq.)
F26
MTR SOUND
0.75 to 15 kHz (6kHz)
kHz 1 2
1Y
F27 (sound tone)
F27
SOUND TONE
0 to 3
-- 0
1Y
F30
FMA (voltage adjust)
F30
FMA V-ADJ 0 to 200%
%
1 100 1 Y
F31
(function)
F31
FMA FUNC
0 to 10
-- 0
1Y
F33
FMP
(pulse rate)
F33
FMP PULSES
300 to 6000 p/s (full scale)
p/s 1 1440
1Y
F34
(voltage adjust)
F34
FMP V-ADJ 0%, 1 to 200%
%
10 1Y
F35
(function)
F35
FMP FUNC
0 to 10
-- 0
1Y
F36
30RY operation mode
F36
30RY MODE 0, 1
-- 0
1Y
F40
Torque limiter1 (driving)
F40
DRV TRQ 1 20 to 150%, 999 % 1
999
1
F41
(braking)
F41
BRK TRQ 1 0%, 20 to 150%, 999
999
1
5-17
F42
Torque vector control 1
F42
TRQVECTOR1 0, 1
-- 0
1N
Name
LCD Display
Setting Range
Y
Y
Y
N
N
Y
N
N
0
0
5-7
5-10
5-11
Pg.
5-12
5-14
5-15
5-16