g GE Industrial Systems
EV200LX SUPPLEMENT
Page 5 of 5 REV 11/2002
Current Limit Adjustments:
01005020 30 4010 70 80 9060
0
150
300
450
600
750
900
1050
1200
1350
1500
Percent On Time
Motor Amperes
P
e
a
k
I
M
M
a
x
i
m
u
m
P
e
a
k
I
M
M
i
n
i
m
u
m
A
v
e
r
a
g
e
I
M
M
a
x
i
m
u
m
A
v
e
r
a
g
e
I
M
M
i
n
i
m
u
m
Peak Motor C/L
@ Typical Motor Inductance
Min-Max @30% ON
TIME
735/1170 Amps
Min-Max @50% ON
TIME
560/990 Amps
Min-Max @70% ON
TIME
390/810 Amps
Average Motor C/L
@ Typical Motor Inductance
Min-Max @30% ON
TIME
615/960 Amps
Min-Max @50% ON
TIME
480/870 Amps
Min-Max @70% ON
TIME
347/750 Amps