A-14 G60 Generator Protection System GE Multilin
A.1 PARAMETER LISTS APPENDIX A
A
9223 Synchchk 2 Delta Phs Degrees Synchrocheck 2 delta phase
9224 Synchchk 3 Delta V Volts Synchrocheck 3 delta voltage
9226 Synchchk 3 Delta F Hz Synchrocheck 3 delta frequency
9227 Synchchk 3 Delta Phs Degrees Synchrocheck 3 delta phase
9228 Synchchk 4 Delta V Volts Synchrocheck 4 delta voltage
9230 Synchchk 4 Delta F Hz Synchrocheck 4 delta frequency
9231 Synchchk 4 Delta Phs Degrees Synchrocheck 4 delta phase
9536 PMU 1 Va Mag Volts Phasor measurement unit 1 phase A voltage magnitude
9538 PMU 1 Va Angle Degrees Phasor measurement unit 1 phase A voltage angle
9539 PMU 1 Vb Mag Volts Phasor measurement unit 1 phase B voltage magnitude
9541 PMU 1 Vb Angle Degrees Phasor measurement unit 1 phase B voltage angle
9542 PMU 1 Vc Mag Volts Phasor measurement unit 1 phase C voltage magnitude
9544 PMU 1 Vc Angle Degrees Phasor measurement unit 1 phase C voltage angle
9545 PMU 1 Vx Mag Volts Phasor measurement unit 1 auxiliary voltage magnitude
9547 PMU 1 Vx Angle Degrees Phasor measurement unit 1 auxiliary voltage angle
9548 PMU 1 V1 Mag Volts Phasor measurement unit 1 positive-sequence voltage magnitude
9550 PMU 1 V1 Angle Degrees Phasor measurement unit 1 positive-sequence voltage angle
9551 PMU 1 V2 Mag Volts Phasor measurement unit 1 negative-sequence voltage magnitude
9553 PMU 1 V2 Angle Degrees Phasor measurement unit 1 negative-sequence voltage angle
9554 PMU 1 V0 Mag Volts Phasor measurement unit 1 zero-sequence voltage magnitude
9556 PMU 1 V0 Angle Degrees Phasor measurement unit 1 zero-sequence voltage angle
9557 PMU 1 Ia Mag Amps Phasor measurement unit 1 phase A current magnitude
9559 PMU 1 Ia Angle Degrees Phasor measurement unit 1 phase A current angle
9560 PMU 1 Ib Mag Amps Phasor measurement unit 1 phase B current magnitude
9562 PMU 1 Ib Angle Degrees Phasor measurement unit 1 phase B current angle
9563 PMU 1 Ic Mag Amps Phasor measurement unit 1 phase C current magnitude
9565 PMU 1 Ic Angle Degrees Phasor measurement unit 1 phase C current angle
9566 PMU 1 Ig Mag Amps Phasor measurement unit 1 ground current magnitude
9568 PMU 1 Ig Angle Degrees Phasor measurement unit 1 ground current angle
9569 PMU 1 I1 Mag Amps Phasor measurement unit 1 positive-sequence current magnitude
9571 PMU 1 I1 Angle Degrees Phasor measurement unit 1 positive-sequence current angle
9572 PMU 1 I2 Mag Amps Phasor measurement unit 1 negative-sequence current magnitude
9574 PMU 1 I2 Angle Degrees Phasor measurement unit 1 negative-sequence current angle
9575 PMU 1 I0 Mag Amps Phasor measurement unit 1 zero-sequence current magnitude
9577 PMU 1 I0 Angle Degrees Phasor measurement unit 1 zero-sequence current angle
9578 PMU 1 Freq Hz Phasor measurement unit 1 frequency
9580 PMU 1 df dt Hz/s Phasor measurement unit 1 rate of change of frequency
9581 PMU 1 Conf Ch --- Phasor measurement unit 1 configuration change counter
10240 SRC 1 Ia THD % Source 1 phase A current total harmonic distortion
10241 SRC 1 Ia Harm[0] % Source 1 phase A current second harmonic
10242 SRC 1 Ia Harm[1] % Source 1 phase A current third harmonic
10243 SRC 1 Ia Harm[2] % Source 1 phase A current fourth harmonic
10244 SRC 1 Ia Harm[3] % Source 1 phase A current fifth harmonic
10245 SRC 1 Ia Harm[4] % Source 1 phase A current sixth harmonic
10246 SRC 1 Ia Harm[5] % Source 1 phase A current seventh harmonic
10247 SRC 1 Ia Harm[6] % Source 1 phase A current eighth harmonic
10248 SRC 1 Ia Harm[7] % Source 1 phase A current ninth harmonic
Table A–1: FLEXANALOG DATA ITEMS (Sheet 14 of 27)
ADDRESS FLEXANALOG NAME UNITS DESCRIPTION