– 41 –
Fault 
Code 
Fault Name and 
Binary Lights Lit
Description Repair Action
11 Clock Monitor 1.  AC power line frequency is not 60Hz.
2. Software failure.
1.  Check the frequency of the AC 
power outlet. If it is more than a 
IHZ+]RȺRI+]QRWLI\XWLOLW\
company.
2.  If house frequency is good, 
update software.
12 Redundant Flood 
Condition
Backup Processor received an extended 
period of pressure readings that is nearing 
RYHUÀRZOHYHOV3UHVVXUHµ
Voltage Output must be present. Could mean 
ZDWHUGLGJHWWKDWKLJKGXHWREULHÀ\VWXFN
water valve. Voltage output of Sensor too high 
for actual water level because of Sensor or 
water in Pressure tube increasing pressure.
•  Check pressure tube for trapped 
water. 
•  Check Each Valves Operation… 
(Replace Water Valve and send 
back to GE)
•  Check the output voltage from 
the pressure sensor to ensure it 
matches the water level in the 
basket according to the pressure 
sensor chart.
13 Redundant Lid 
Unlocked
In spin mode, the lid switch feedback 
has voltage (lid closed), for more than 
5 seconds the motor speed feedback 
assumes the basket is spinning > 4-5RPM 
when the lid lock feedback has no voltage 
(Lid Unlocked).
Lid Switch Feedback has no Voltage when 
the BRPM is > 4-5RPM.
•  Check lid switch continuity at 
J513 on the control.
•  Check continuity of lid lock 
position. Opened or Closed. 
•  Check for proper operation of lid 
lock. 120VAC while activating
•  Check lid lock wiring harness 
from the control to lock 
assembly.
14 Lid Lock Fault Signal received by control is indicating the 
lock will not lock or unlock when requested 
or the lid switch is indicating open when the 
signal received indicated locked.
•  Verify that the lid lock is not 
blocked by any external debris.
•  Check lid switch continuity at 
J513 on the control.
•  Check continuity of lid lock 
position. Opened or Closed. 
•  Check for proper operation of lid 
lock. 120 VAC while activating
•  Check lid lock wiring harness 
from the control to lock 
assembly.
•  If lid lock assembly and harness 
are OK, update the software.
15 Water Temp Sensor 
Invalid
1. Thermistor disconnected/not present.
2. Failed thermistor
•  
Check thermistor resistance 
from connector J701 on the 
control board. Validate the 
resistance matches the table in 
mini-manual.
•  Check wiring harness and 
connections.
• Replace thermistor.
16 Adaptive Drain/Slow 
Drain
The total number of times during machine 
life the actual amount of time the pressure 
sensor indicated the wash water had drained 
to empty exceeded the calculated time by the 
software.
•  This fault is set when adaptive 
drain cycle occurs to try to 
remove the rest of water in tub..
•  If the adaptive drain cycle times 
out, the control will run a Drain 
Pump Clearing algorithm to free 
the pump impeller of debris. 
7KHQLWZLOO¿QLVKGUDLQLQJ,IGUDLQ
clearing algorithm fails look for 
fault 18.
•  If fault 16 is 100 and fault 
18 never occurs there is no 
problem…If fault 16 and fault 18 
equal each other in faults, then 
look for drain blockages including 
house standpipe.
32    16     8      4      2     1
(Continued next page)