– 42 –
The thermistor and harness comes as one 
assembly that connects to the control board. 
The thermistor also comes with an O-ring that 
creates a water tight seal around the probe.
When reinstalling the thermistor, ensure that the 
thermistor is seated properly. If it bulges, it will not 
seal properly.
  Thermistor
Bulging O-ring
Thermistor Resistance Table
Temp 
(°C)
Temp 
(°F)
5HVLVWDQFH
10 50 19901
15 59 15713
20 68 12493
28 82.4 8833
32 90 7446
38 100 5807
44 111 4558
50 122 3601
54 130 3108
66 150 2016
76 169 1435
  Bleach/Bulk Tank Funnel 
The bleach portion of the funnel directs the liquid 
bleach to the top cover, dispensing it between the 
outer tub and the basket. There is no water valve 
to rinse the funnel after use. The bulk tank portion 
of the funnel directs the liquid detergent into the 
bulk tank.
Bleach/Bulk Tank Funnel Removal
1.  To remove the bleach/bulk tank funnel, reach 
between the top cover and tub cover and 
push up on the bottom of the funnel.
2.  Removing the funnel gives access to the bulk 
tanks 3/8 in. mounting bolt. 
3.  To install the funnel onto the top cover, push 
down on the funnel to seat it into position.
B u l k   Ta n k  
Mounting Bolt