– 50 –
3.  Disconnect the harness connector for the 
recirculation pump.
4.  Disconnect the wire tie securing the harness 
to the platform assembly.  A new wire tie 
comes attached to the drain pump harness.
5.  Remove three 3/8 hex head bolts securing the 
pump to the tub.
6.  Pull the pump away from the tub.  Be sure the 
VHDOFRPHVRႇZLWKWKHSXPS
The seal comes with a new pump but can be 
ordered separately.
The recirculation pump is located on the bottom 
front of the tub and is mounted directly to the 
bottom of the tub. The recirculation pump is a 
120 VAC pump used to recirculate water from the 
tub assembly, up through a tube to the top of the 
basket. The recirculation pump utilizes the tub 
cover to spray water over the clothes. 
Recirculation Pump 'LDJQRVWLFV
1.  Disconnect power to the washer and access 
the control board.
2.  Disconnect the J512 connector from the 
board.
3.  Check resistance from pin 1 (brown wire) to 
pin 6 (red wire). The resistance should read 
approximately 31.7 ohms. If the resistance is 
within range, ensure that the pump has 120 
VAC at the pump harness connector.
Recirculation Pump and Tube Removal
Before removing the drain or recirculation pump, 
any water in the basket must be removed. If the 
drain pump is inoperable, water can be removed  
by using a transfer pump shown on the following 
page.
Lean the washer back using ergo-assisting prop 
blocks or lay the washer on its side to access the 
bottom of the tub.
1.  Disconnect the recirculation tube from the 
recirculation pump.
2.  Pull downward on the tube to disengage it 
from the tub.
Pump Seal
  Recirculation Pump
Wash System