J702
J803
/
Water Valves
/
Test Resistance of the Valve from the corresponding
colored wire on the Invertor board at connector J702 to
the J803 connector on the Invertor board. 120VAC power
supply to the valve. Approx. 1 K ohm resistance on the
coils.
If you do not have any resistance, make sure that the
common neutral wire connecter is connected.
Common Neutral