2 C
CUTOUT FOR DOUBLE OVENS
(2 THERMAL OVENS)
NOTE: If the cabinet does not have a front frame and the sides are less than ¾” (1.9 cm) thick, shim
both sides equally to establish the cutout width.
Dim. Description 27” Double Oven 30” Double Oven with
Pedestal
30” Double Oven
without Pedestal
A Cabinet Width 27” (68.6 cm) 30” (76.2 cm) 30” (76.2 cm)
B Cutout Width 25” (63.5 cm) min.
25
1
4” (64.1 cm) max.
28
1
2” (72.4 cm) min.
28
5
8” (72.7 cm) max.
28
1
2” (72.4 cm) min.
28
5
8” (72.7 cm) max.
C Cutout Height
49
11
16” (126.2 cm) min.
50
1
8” (127.3 cm) max.
51
13
16” (131.6 cm) min.
51
15
16” (131.9 cm) max.
50 ¼” (127.64cm)
D Overlap of Oven
Over Side Edges
of Cutout
1” (2.5 cm)
11
16” (1.75 cm)
11
16” (1.75 cm)
E
Clearance to
Adjacent Corners,
Drawers, Walls, etc.,
When Door Is Open
23” (50.8 cm) min. 23” (53.3 cm) min. 23” (53.3 cm) min.
F Overlap of Oven
Top of Cutout
1” (2.5 cm) min. 1” (2.5 cm) min.
(1
1
4” (3.2 cm) for PT9550)
1” (2.5 cm) min.
(1
1
4” (3.2 cm) for PT9550)
G Overlap of Oven
Bottom of Cutout
1” (2.5 cm) min. 1
1
4” (3.2 cm) 1
1
4” (3.2 cm)
H Junction Box
Location
8
3
4” (22.2 cm) max.
right side only
9
1
2” (24.1 cm) max.
right side only
9
1
2” (24.1 cm) max.
right side only
J Height to Bottom
of Junction Box
44” (111.8 cm) 47” (119.4 cm) 47” (119.4 cm)
K Recommended
Cutout Location
from Floor
13
1
4” (33.7 cm) 12” (30.5 cm) 12” (30.5 cm)
31-10856-1
04-13 GE
2 D
CUTOUT FOR INSTALLATION OVER A WARMING DRAWER
NOTE: Install the oven only with specific models listed on the label located on top of the oven.
NOTE: Additional clearances between cutouts may be required. Check to be sure the oven supports
above the Warming Drawer location do not obstruct the required interior depth and height.
When installing a Warming Drawer below a single or double oven, a separate 120V, 60 HZ, properly
grounded receptacle must be installed. Refer to installation instructions packed with
the Warming Drawer for specific installation requirements.
Anti-Tip Block Against
Rear Wall Per Warming
Drawer Requirement
2" (5.1 cm)
Min.
Per Warming
Drawer
Requirement
Continue to Section 3 for DWO with Pedestal. Otherwise, continue to Section 4.
Continue to Section 3.
H
B
C
K
F
G
D
A
J
E
Junction
Box
Location
(junction
box may
be located
in adjacent
cabinet)
Cutout Depth
23-1/2”
(59.7 cm) Min.

Other manuals for GE JK3000SFSS