GE Multilin L30 Line Current Differential System 5-145
5 SETTINGS 5.5 FLEXLOGIC
5
FIXED OPERANDS Off Logic = 0. Does nothing and may be used as a delimiter in an equation list;
used as ‘Disable’ by other features.
On Logic = 1. Can be used as a test setting.
INPUTS/OUTPUTS:
Contact inputs
Cont Ip 1 On
Cont Ip 2 On
↓
Cont Ip 1 Off
Cont Ip 2 Off
↓
Cont Ip 96 On
Cont Ip 96 Off
(will not appear unless ordered)
(will not appear unless ordered)
↓
(will not appear unless ordered)
(will not appear unless ordered)
↓
(will not appear unless ordered)
(will not appear unless ordered)
INPUTS/OUTPUTS:
Contact outputs
Cont Op 1 Closed
Cont Op 1 IOn
Cont Op 1 VOn
Cont Op 1 VOff
Contact output is closed
Current is flowing through the contact
Voltage exists across the contact (present for contact outputs equipped with
monitoring)
Voltage exists across the contact (present for contact outputs equipped with
monitoring)
Cont Op 2 to 64 Same set of operands as shown for Cont Op 1
INPUTS/OUTPUTS:
Direct input
Direct I/P 1-1 On
↓
Direct I/P 1-8 On
(appears only when an inter-relay communications card is used)
↓
(appears only when inter-relay communications card is used)
Direct I/P 2-1 On
↓
Direct I/P 2-8 On
(appears only when inter-relay communications card is used)
↓
(appears only when inter-relay communications card is used)
INPUTS/OUTPUTS:
Remote double-
point status inputs
RemDPS Ip 1 BAD
RemDPS Ip 1 INTERM
RemDPS Ip 1 OFF
RemDPS Ip 1 ON
Asserted while the remote double-point status input is in the bad state
Asserted while the remote double-point status input is in the intermediate
state
Asserted while the remote double-point status input is off
Asserted while the remote double-point status input is on
REMDPS Ip 2 to 5 Same set of operands as per REMDPS 1
INPUTS/OUTPUTS:
Remote inputs
REMOTE INPUT 1 On
REMOTE INPUT 2 On
REMOTE INPUT 3 On
↓
REMOTE INPUT 32 On
Flag is set, logic=1
Flag is set, logic=1
Flag is set, logic=1
↓
Flag is set, logic=1
INPUTS/OUTPUTS:
Virtual inputs
Virt Ip 1 On
Virt Ip 2 On
Virt Ip 3 On
↓
Virt Ip 64 On
Flag is set, logic=1
Flag is set, logic=1
Flag is set, logic=1
↓
Flag is set, logic=1
INPUTS/OUTPUTS:
Virtual outputs
Virt Op 1 On
Virt Op 2 On
Virt Op 3 On
↓
Virt Op 96 On
Flag is set, logic=1
Flag is set, logic=1
Flag is set, logic=1
↓
Flag is set, logic=1
LED INDICATORS:
Fixed front panel
LEDs
LED IN SERVICE
LED TROUBLE
LED TEST MODE
LED TRIP
LED ALARM
LED PICKUP
LED VOLTAGE
LED CURRENT
LED FREQUENCY
LED OTHER
LED PHASE A
LED PHASE B
LED PHASE C
LED NEUTRAL/GROUND
Asserted when the front panel IN SERVICE LED is on
Asserted when the front panel TROUBLE LED is on
Asserted when the front panel TEST MODE LED is on
Asserted when the front panel TRIP LED is on
Asserted when the front panel ALARM LED is on
Asserted when the front panel PICKUP LED is on
Asserted when the front panel VOLTAGE LED is on
Asserted when the front panel CURRENT LED is on
Asserted when the front panel FREQUENCY LED is on
Asserted when the front panel OTHER LED is on
Asserted when the front panel PHASE A LED is on
Asserted when the front panel PHASE B LED is on
Asserted when the front panel PHASE C LED is on
Asserted when the front panel NEUTRAL/GROUND LED is on
LED INDICATORS:
LED test
LED TEST IN PROGRESS An LED test has been initiated and has not finished
LED INDICATORS:
User-programmable
LEDs
LED USER 1 Asserted when user-programmable LED 1 is on
LED USER 2 to 48 The operand above is available for user-programmable LEDs 2 through 48
Table 5–17: L30 FLEXLOGIC OPERANDS (Sheet 6 of 7)
OPERAND TYPE OPERAND SYNTAX OPERAND DESCRIPTION