A-4 L30 Line Current Differential System GE Multilin
A.1 PARAMETER LISTS APPENDIX A
A
7202 SRC 2 Pa Watts Source 2 phase A real power
7204 SRC 2 Pb Watts Source 2 phase B real power
7206 SRC 2 Pc Watts Source 2 phase C real power
7208 SRC 2 Q Vars Source 2 three-phase reactive power
7210 SRC 2 Qa Vars Source 2 phase A reactive power
7212 SRC 2 Qb Vars Source 2 phase B reactive power
7214 SRC 2 Qc Vars Source 2 phase C reactive power
7216 SRC 2 S VA Source 2 three-phase apparent power
7218 SRC 2 Sa VA Source 2 phase A apparent power
7220 SRC 2 Sb VA Source 2 phase B apparent power
7222 SRC 2 Sc VA Source 2 phase C apparent power
7224 SRC 2 PF --- Source 2 three-phase power factor
7225 SRC 2 Phase A PF --- Source 2 phase A power factor
7226 SRC 2 Phase B PF --- Source 2 phase B power factor
7227 SRC 2 Phase C PF --- Source 2 phase C power factor
7552 SRC 1 Frequency Hz Source 1 frequency
7554 SRC 2 Frequency Hz Source 2 frequency
8672 Brk 1 Arc Amp A
kA
2
-cyc
Breaker 1 arcing amp phase A
8674 Brk 1 Arc Amp B
kA
2
-cyc
Breaker 1 arcing amp phase B
8676 Brk 1 Arc Amp C
kA
2
-cyc
Breaker 1 arcing amp phase C
8678 Brk 1 Op Time A ms Breaker 1 operating time phase A
8679 Brk 1 Op Time B ms Breaker 1 operating time phase B
8680 Brk 1 Op Time C ms Breaker 1 operating time phase C
8681 Brk 1 Op Time ms Breaker 1 operating time
8682 Brk 2 Arc Amp A
kA
2
-cyc
Breaker 2 arcing amp phase A
8684 Brk 2 Arc Amp B
kA
2
-cyc
Breaker 2 arcing amp phase B
8686 Brk 2 Arc Amp C
kA
2
-cyc
Breaker 2 arcing amp phase C
8688 Brk 2 Op Time A ms Breaker 2 operating time phase A
8689 Brk 2 Op Time B ms Breaker 2 operating time phase B
8690 Brk 2 Op Time C ms Breaker 2 operating time phase C
8691 Brk 2 Op Time ms Breaker 2 operating time
9024 Prefault Ia Mag [1] Amps Fault 1 pre-fault phase A current magnitude
9026 Prefault Ia Ang [1] Degrees Fault 1 pre-fault phase A current angle
9027 Prefault Ib Mag [1] Amps Fault 1 pre-fault phase B current magnitude
9029 Prefault Ib Ang [1] Degrees Fault 1 pre-fault phase B current angle
9030 Prefault Ic Mag [1] Amps Fault 1 pre-fault phase C current magnitude
9032 Prefault Ic Ang [1] Degrees Fault 1 pre-fault phase C current angle
9033 Prefault Va Mag [1] Volts Fault 1 pre-fault phase A voltage magnitude
9035 Prefault Va Ang [1] Degrees Fault 1 pre-fault phase A voltage angle
9036 Prefault Vb Mag [1] Volts Fault 1 pre-fault phase B voltage magnitude
9038 Prefault Vb Ang [1] Degrees Fault 1 pre-fault phase B voltage angle
9039 Prefault Vc Mag [1] Volts Fault 1 pre-fault phase C voltage magnitude
9041 Prefault Vc Ang [1] Degrees Fault 1 pre-fault phase C voltage angle
9042 Fault Ia Mag [1] Amps Fault 1 phase A current magnitude
9044 Fault Ia Ang [1] Degrees Fault 1 phase A current angle
9045 Fault Ib Mag [1] Amps Fault 1 phase B current magnitude
Table A–1: FLEXANALOG DATA ITEMS (Sheet 4 of 9)