Table 10. Log messages
Display Description
TXlobat Transmitter low battery
ZN Lost Zone lost - A wireless multiplexed zone device is not
reporting to the control.
Duress The control has been armed or disarmed with a Duress
code.
Man Fire Manual fire - Touchpad Fire has been activated.
Aux 2 Auxiliary 2 - Touchpad Medical has been activated.
Panic Touchpad Panic has been activated.
KP Tamper Touchpad Tamper - The touchpad tamper has been
activated.
BoxTamp Box Tamper - The box tamper circuit has been acti-
vated.
AC Fail AC failure has been detected.
OverCur Over current - A short circuit of a power supply has
occurred.
Srn Tamp Siren tamper - A siren or speaker tamper has been
detected.
Tel Flt Telephone fault - A telephone fault or tamper has been
detected.
Exp Trb Expansion trouble - An expansion device or touchpad is
not reporting to the control.
Log Full The event log is full.
Open Reports, user number, date, time and partition of
opening.
Close Reports, user number, date, time and partition of
closing.
Exit Err Exit error - Entry/exit zone was faulted when the exit
delay expired.
Rec Close Recent close - An alarm occurred within 5 minutes of
the control being armed.
Autotest Automatic test - Sending a communicator test at a
specified interval.
Start Prog Start programming - Local Programming has started.
End Prog End programming -Local programming has ended.
Start Dnld Start download - Download session has started.
End Dnld End download - Download session has ended.
Cancel Cancel was initiated within 5 minutes of an alarm.
Gnd Flt Ground fault - A short to ground has been detected.
Man Test Manual test - Bell and/or communicator test while
system is disarmed.
Re-exit The exit delay has been restarted without disarming the
system.
Output Trip A trip has occurred on an expander auxiliary output.
Data Lost Communication of a signal has failed (log only event).
Walk-test A zone Walk Test mode has been activated.
End Test Test has ended.
Cross-Trip The first zone of a cross zone has been tripped (log
event only).
Expansion Event An expansion module has created an unidentified
event.
Partial Arm Reports a closing in stay mode.
Listen In A listen-in function has been activated.
Service Start Technician is on site.
Service End Technician is off site.
Code Entry A code has been entered.
First Open Reports when the first partition is disarmed.
Last Close Reports when the last partition is armed.
Sprnklr Sprinkler - Instant sprinkler supervisory report.
Clock Set Clock has been reset.
RF Jammed A wireless expansion module is jammed.
CleanMe A smoke detector requires cleaning.
Table 10. Log messages (continued)
Display Description

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NX-148E-RF and is the answer not in the manual?

GE NX-148E-RF Specifications

Power IconPower
power requirements12.0 VDC (provided by panel)
current draw75 mA maximum
Operating Environment IconOperating Environment
operating temperature32° to 120°F (0° to 49°C)
storage temperature-30° to 140°F (-34° to 60°C)
humidity90% relative, non-condensing
Wireless Specifications IconWireless Specifications
frequency319.5 MHz
wireless range600 feet (183 m) open air
Weight and Dimensions IconWeight and Dimensions
dimensions5 x 6 x 1 in. (12.7 x 15.2 x 2.5 cm)