[*]-[6] ASSIGNING AUTHORITY LEVEL
Note: You must be authorized to access the partition that you wish to add to, or remove from,
another person’s authority.
1. Enter [*]-[6] The LCD screen will prompt for a code.
2. Enter [master code] The LCD screen will prompt for a user number.
3. Enter the 2 digit user number
(always 2 digits, i.e. “03” for
user 3)
The LCD screen will prompt for a new code. The LCD
will now prompt you for the first in the following list of
attributes.
PROMPTS
Outputs used?
Open / close report?
Bypass enable?
Arm / disarm?
If prompt 1 (“Outputs used?”)
is answered NO, the LCD will
display the four messages
below
If prompt 1 (“Outputs used?”)
is answered YES, the LCD will
display the four messages
below
Master code? Output 4 enable?
Sched. arm only? Output 3 enable?
Arm only? Output 2 enable?
Reserved Output 1 enable?
4 Enter a partition number. The LCD screen will prompt you for the next user
code.
Note: The default allows access to all partitions. The first keypress will remove access to
the partition. To re-establish access, press the partition number again. When
completed, press [*].
5. If another user code needs to be programmed, return to step 3.
6. To exit this feature, press [#].
NOTE:
WHEN PROGRAMMING THE USER CODES FOR A PARTITIONED SYSTEM, LEAVE AT LEAST ONE
CODE WITH ACCESS TO ALL PARTITIONS. UNLESS YOU DO THIS, YOU WILL NOT BE ABLE TO
ADD NEW USERS. (THE CODE CAN BE THE “GO TO PROGRAM CODE”, IF ENABLED IN
LOCATION 43 OF THE NX-4 CONTROL PANEL). IF YOU WANT TO LET THE END USER ADD
NEW CODES, YOU MUST REMOVE THE PARTITION AUTHORITY FROM ALL BLANK CODES.
NX-4-EUR Installation manual Page 24 02/07/06