Reporting events to phone number 1
Phone N°1 has two programming locations that are used to select the events which are
reported to this phone number.
Location 4 is used to select which events are reported to phone N°1. Location 5 is used to
select which partitions are reported to phone N°1. If you do not want dual or split reporting,
use location 4 to select all events to phone N°1, and leave location 5 at the factory default of
“0”. If you want dual or split reporting, and the split is based on the event type (such as alarm,
open/close, etc.), you should use location 4 to select only those events that should be reported
to phone N°1, and you should leave location 5 at the factory default of “0”. If you want dual or
split reporting, and the split is based on partition, you should program location 4 as a “0” and
use location 5 to select those partitions that are to be reported to phone N°1. If no events are
to be reported to phone N°1, both locations should be programmed as “0”.
LOCATION 4 - EVENTS REPORTED TO PHONE N° 1 (2 segments, feature selection data)
Segment 1
1 = Alarms
2 = Opening and closings
3 = Zone bypass and bypass restores
4 = Zone trouble and trouble restores
5 = Power fail (AC failure), low battery, power restore (AC restore) , and low
battery bestore
6 = Bell cut, bell cut restore, telephone line restore
7 = Test reports
8 = Start and end programming, download complete and log full
Segment 2
1 = Zone and box tamper
2 = Auxiliary power over-current, and restore
3 = Wireless sensor missing and restore
4 = Wireless sensor low battery and restore
5 = Expander trouble and restore (keypads are considered as expanders)
6 = Fail to communicate
7 = Alarm restore
8 = Tamper restore
LOCATION 5 - Reserved