Test 4 – Drain Pump Check
The display will initially show “t4”.
Once the start button is pushed, the Display will
initially toggle between “t4” and the water level.
The drain pump will be enabled for a maximum
of 60 seconds (or until the Power or Start button
is pressed). Once the 60 seconds has elapsed,
the control will go back to the “t4” state. At this
time, the display will toggle between “t4” and the
water level with the drain pump off. When Start
button is pressed, returns to “t4”test.
When Cycle button is pressed, exit the test and
move to next test “t5”.