Important Safety Information .................3
Installation Instructions
........................... 4
Controls
.......................................................... 8
Controls and Operating Functions
..... 9
On Board Diagnostics
.............................. 11
Fault Codes
................................................. 12
Wiring Diagram
......................................... 13
Testing the Thermostat
..........................14
Troubleshooting
........................................ 16
Limited Warranty
...................................... 17
Consumer Support
................................... 18
49-5000400 Rev. 5
05-21 GEA
THERMOSTAT
OWNER’S MANUAL
& INSTALLATION
INSTRUCTIONS
RARWT_ _ (Single Zone Smart T.Stat)
RARMC_ _ (Standard Ceiling Control)
RAREC3A (Standard Ceiling Control)
RAREC2A (Direct Wire or Smart T.Stat)
RAREC1A (RV-C or Smart T.Stat Control)
Write the model and serial numbers
here:
Model #
____________________
Serial # ____________________
You can find them on a label on the
thermostat.
GE is a trademark of the General Electric Company.
Manufactured under trademark license.
Single Zone RV

Questions and Answers

  • C
    Cody PhillipsAug 12, 2025
    Why compressor does not turn on immediately on GE Thermostat?
    • E
      Erika SawyerAug 12, 2025
      This is normal behavior. The GE Thermostat has a built-in 3-minute OFF timer to prevent the compressor from being turned off and immediately back on.
  • D
    duranyolandaAug 16, 2025
    What to do if the display is blank on GE RAREC1A Thermostat?
    • C
      Crystal KingAug 16, 2025
      If the display is blank, check that 12VDC is present. The display will be blank when 12V is not present.
  • C
    chapmandanielAug 19, 2025
    What to do if all GE Thermostat buttons are non-responsive?
    • G
      Gabriella SmithAug 20, 2025
      If all the thermostat buttons are non-responsive, verify that 12VDC is present. The unit will not operate when the voltage is below 10.5V.
  • D
    David DavisAug 23, 2025
    What to do if the fan runs continuously on GE Thermostat?
    • R
      ramirezdavidAug 23, 2025
      Check the Fan Mode setting. If it is set to FAN ON, the fan will run continuously.
  • G
    george39Aug 27, 2025
    What to do if fan and compressor will not turn on GE RAREC1A Thermostat?
    • C
      christopherfigueroaAug 27, 2025
      Verify that 115VAC is present.
  • A
    anthonyholmesAug 30, 2025
    Why fan does not turn on immediately on GE RAREC1A Thermostat?
    • A
      April MartinezAug 31, 2025
      In Heat-Pump mode, if Auto Fan is selected, the fan will not turn ON until the compressor turns ON after the 3 minute OFF timer.
  • J
    jonathanmorenoSep 4, 2025
    What to do if the fan does not turn on, but the compressor does on GE Thermostat?
    • K
      Karen DouglasSep 4, 2025
      With power removed, check that nothing is obstructing the fan blade and that it spins freely. Also, check the 5 amp Fuse on the board.
  • T
    Tonya DaughertySep 7, 2025
    What to do if room temperature does not match setpoint on GE RAREC1A Thermostat?
    • D
      Derrick SteeleSep 7, 2025
      Verify proper installation. Ensure the thermostat is not on an exterior wall, in direct sunlight, or in an area affected by a vent or duct.

Summary

Safety Information and Specifications

Installation Guide

Removing Existing Thermostat

Step-by-step instructions for safely removing the old thermostat from the wall.

Installing New Thermostat and Control

Instructions for mounting the new thermostat and connecting its main control box.

Thermostat Operation and Controls

Mode Selection and System Modes

Explains how to select modes like Off, Fan Only, Cool, Heat Pump, and Furnace.

System Diagnostics and Error Codes

On-Board Diagnostic Indicators

Explains diagnostic icons and messages such as Low Voltage and Freeze-Up.

Heat-Pump Over Temperature Alerts

Describes the alert for heat-pump indoor coil overheating and compressor shutdown.

Interpreting Fault Codes

Lists and explains various fault codes displayed by the thermostat.

Wiring Diagrams and Connections

Testing Thermostat Functionality

Troubleshooting Common Issues

GE RAREC1A Specifications

General IconGeneral
BrandGE
ModelRAREC1A
CategoryThermostat
LanguageEnglish

Related product manuals