GE Multilin T35 Transformer Protection System B-53
APPENDIX B B.4 MEMORY MAPPING
B
C630 ...Repeated for Direct Output 17
C633 ...Repeated for Direct Output 18
C636 ...Repeated for Direct Output 19
C639 ...Repeated for Direct Output 20
C63C ...Repeated for Direct Output 21
C63F ...Repeated for Direct Output 22
C642 ...Repeated for Direct Output 23
C645 ...Repeated for Direct Output 24
C648 ...Repeated for Direct Output 25
C64B ...Repeated for Direct Output 26
C64E ...Repeated for Direct Output 27
C651 ...Repeated for Direct Output 28
C654 ...Repeated for Direct Output 29
C657 ...Repeated for Direct Output 30
C65A ...Repeated for Direct Output 31
C65D ...Repeated for Direct Output 32
Reset (Read/Write Setting)
C750 FlexLogic operand which initiates a reset 0 to 4294967295 --- 1 F300 0
Control Pushbuttons (Read/Write Setting) (7 modules)
C760 Control Pushbutton 1 Function 0 to 1 --- 1 F102 0 (Disabled)
C761 Control Pushbutton 1 Events 0 to 1 --- 1 F102 0 (Disabled)
C762 ...Repeated for Control Pushbutton 2
C764 ...Repeated for Control Pushbutton 3
C766 ...Repeated for Control Pushbutton 4
C768 ...Repeated for Control Pushbutton 5
C76A ...Repeated for Control Pushbutton 6
C76C ...Repeated for Control Pushbutton 7
Force Contact Inputs/Outputs (Read/Write Settings)
C7A0 Force Contact Input x State (96 items) 0 to 2 --- 1 F144 0 (Disabled)
C800 Force Contact Output x State (64 items) 0 to 3 --- 1 F131 0 (Disabled)
Direct Inputs/Outputs (Read/Write Setting)
C880 Direct Device ID 1 to 16 --- 1 F001 1
C881 Direct I/O Channel 1 Ring Configuration Function 0 to 1 --- 1 F126 0 (No)
C882 Platform Direct I/O Data Rate 64 to 128 kbps 64 F001 64
C883 Direct I/O Channel 2 Ring Configuration Function 0 to 1 --- 1 F126 0 (No)
C884 Platform Direct I/O Crossover Function 0 to 1 --- 1 F102 0 (Disabled)
Direct Input/Output Commands (Read/Write Command)
C888 Direct Input/Output Clear Counters Command 0 to 1 --- 1 F126 0 (No)
Direct Inputs (Read/Write Setting) (32 modules)
C890 Direct Input 1 Device Number 0 to 16 --- 1 F001 0
C891 Direct Input 1 Number 0 to 96 --- 1 F001 0
C892 Direct Input 1 Default State 0 to 3 --- 1 F086 0 (Off)
C893 Direct Input 1 Events 0 to 1 --- 1 F102 0 (Disabled)
C894 ...Repeated for Direct Input 2
C898 ...Repeated for Direct Input 3
C89C ...Repeated for Direct Input 4
C8A0 ...Repeated for Direct Input 5
C8A4 ...Repeated for Direct Input 6
C8A8 ...Repeated for Direct Input 7
C8AC ...Repeated for Direct Input 8
C8B0 ...Repeated for Direct Input 9
C8B4 ...Repeated for Direct Input 10
C8B8 ...Repeated for Direct Input 11
C8BC ...Repeated for Direct Input 12
Table B–10: MODBUS MEMORY MAP (Sheet 45 of 52)
ADDR REGISTER NAME RANGE UNITS STEP FORMAT DEFAULT