Troubleshooting Flowcharts
L3 Dryer - Electric Model
Dryer
Enter field service
mode (disconnect/
reconnect power, then
press and hold
Start
and
Cotton
buttons).
Unit will start
and run. Continue to
hold buttons until
diagnostics mode is
entered.
Press
Mixed Loads
button - DSSD output
displays error codes for
existing errors.
Press
Stop
to exit field
service mode.
House fuse, breaker,
wall outlet problem.
Proper voltage to
Dryer.
DSSD output displays
Fd
,
EL
, and EEPROM
version number.
E0
E1
Sensor Rods, Circuit
Problem, Shorted
dO
E2
Thermistor, No Error.
H1
Heater 1 Turns
ON, Outer
Door Open
H2
Sn
Heater 2 Turns ON
(1 OFF), Inner
Motor Switches ON
No
Yes
Test
Mode.
Check error codes.
Thermistor Error or
Board.
S0
Sensor Rods, Open
Circuit, Normal
Door Closed
dC
Not Connected to
Circuit - Check
connection.
Capacitor Leaks -
Replace capacitor.
No Fault, Rods OK.
E2
SS
SS
Touch rods
with hand for
20 seconds.
Touch rods
with hand for
20 seconds.