EN
20
B249-005 © 12-2013
964.874.00.0 (04)
NOTE
Pressing jaws are wearing parts. Frequent pressing will
cause the material to become worn; advanced stages of
wear will be indicated by cracks in the material. Pressing
jaws that display this kind of wear or are damaged in any
other way may break, particularly if they are used incorrectly
(e.g. pressing a fitting that is too large, tilting, foreign bodies
on the fitting) or in a way that does not comply with their
intended use.
CAUTION
Danger of crushing by moving parts
` Do not place any part of your body or other objects in
between the pressing jaws
` Do not hold the pressing jaw with your hands during the
pressing sequence
CAUTION
Leaking connection due to failed pressing sequence
` Ensure the pressing jaw is completely closed after the
pressing sequence
` Have any pressing jaws that have not been closed
completely, as well as the pressing tool, inspected for
damage by an authorised repair shop
` Replace any connections that have not been pressed
correctly and do not attempt corrective pressing
` If there are any burrs on the pressfitting after the
pressing sequence, have the pressing jaw inspected by
an authorised repair shop