1
boost level
maintenance level
Use a test kit to check the bromine level. It should
be between 3-5 ppm. If the bromine level stays
within that range for 3 consecutive days, your
maintenance level is well adjusted.
modify the boost level
Boost mode is activated automatically 5 minutes
after starting a pump. Boost mode increases
the bromine generation rate to keep the water
clear, clean and soft. As a rule of thumb, its level
correspond to the number of bathers.
To modify the boost level, slide the right wheel
until the boost icon is highlighted in the middle
and use the up or down arrow keys to adjust the
level.
Click on the the level icon to confirm your
selection.
modify the maintenance level
To verify or modify the maintenance level, slide
the right wheel until the maintenance icon is
highlighted in the middle.
The recommended maintenance level is 12.
Use the up or down arrow keys to adjust the level.
Note that the level can be adjusted by increment
of 2 using the up and down arrow keys.
Please note that it is not recommended to change
the maintenance level at steps greater than 2.
A confirmation will be asked by the system if
you do.
If you do, retest the bromine level the day after.
If the bromine is not in the 3-5 range and is
higher than 5 ppm, decrease the maintenance
level. If the bromine is lower than 3 ppm, increase
it. Repeat until the test reads a bromine level in
the 3-5 range.