Y Series TechBook
13
98
Lamp test
All the segments and LEDs 
light up
Software revision Low-level selection
Low-level selected from 
low-level menu
Software number
8.8.8
Boot up display sequence (Each parameter is displayed for 2 seconds)
Power-up & breaker setting
IMPORTANT! Read before starting
Turn off the breaker.
Make sure all accessories are linked to the bonding connector and connected
to pack.
A minimum ow rate of 18 GPM is required. Make sure that all valves are open in
the spa plumbing and that you have good water ow circulation from the primary
pump into the heater.
Turn on the breaker.
The values displayed by 
the system correspond 
to 08 of the maximum 
amperage capacity of
the GFCI
Use the Up/Down buttons
to select the desired value 
The value can typically be 
modied from 10 to 48 A
Press the Prog button 
to set breaker rating
This table shows typical 
settings of b for different 
GFCI ratings Select the one 
that matches your breaker
GFCI b
60 A 48 A
50 A 40 A
40 A 32 A
30 A 24 A
20 A 16 A
Note: Every OEM has its own
preset congurations.
98
It's important to specify 
the current rating of
the GFCI used to ensure 
safe and efcient current 
management (and reduce 
nuisance GFCI trippings)
Press and hold the Prog
button until you access
the breaker setting menu
(programming menu will
appear rst).
Note: if the keypad in use
does not have the Prog key,
use the Light key instead.
in.o dry-re protection
At power up, the ino detector performs a ow check through the following process:
Pump 1 or circulation pump starts for 2 minutes 
The display will show "_ _ " during the check ow process After 2 minutes the system validates proper water ow
In case of failure, the system tries again The water temperature is shown on the keypad display Once the water has
reached the set point value plus 08˚F the heater is turned off
.
Chose the number of
phases supplying your spa
Use the Up/Down key to 
chose the desired value 
and press the Program or 
light key to conrme the 
selection You can choose 
between 1, 2 or 3 phases
Number of phase selection
UL Menu not 
available
CE 1, 2 or 3
UL Swim* 1 or 2
CE Swim* 1, 2 or 3
*See Swim Spa manual
for details.
4 8

Table of Contents

Other manuals for Gecko Y Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gecko Y Series and is the answer not in the manual?

Gecko Y Series Specifications

General IconGeneral
BrandGecko
ModelY Series
CategorySpa Accessories
LanguageEnglish

Related product manuals