Y Series TechBook
Device Voltage Maximum current ye-3* ye-5
yt-7
* 6
yt-12
* 7
Pump 1 (2-spd) 230 V 15 FLA/60 LRA (inrush)
Pump 2 (2-spd) 230 V 15 FLA/60 LRA (inrush)
* 1
* 3
Pump 3 (2-spd) 230 V 15 FLA/60 LRA (inrush)
* 4
Pump 4 (2-spd) 230 V 15 FLA/60 LRA (inrush)
Pump 5 (1-spd) 230 V 15 FLA/60 LRA (inrush)
O3/CP 230 V 6 FLA/10 A
* 2
A1 230 V 15 FLA/60 LRA (inrush)
Blower 230 V 15 FLA/60 LRA (inrush)
CP
230 V 6 FLA/10 A
O3
230 V 6 FLA/10 A
Direct out 1
230 V 10 A (always on)
* 5
Direct out 2
230 V 10 A (always on)
*
1
Pump #2 can only be installed if Pump #1 is a single-speed pump
*
2
Total of Pump #1-low (or Pumps #2) and O3/ CP cannot exceed 20 FLA
*
3
Total of Pump #2 and Pump #3 cannot exceed 20 FLA
*
4
Pump #3 can only be installed if Pump #2 is a single-speed pump
*
5
Total of Pump #1-low,O3/ CP, and Direct #1 cannot exceed 20 FLA
* 
6
If CP is used, Pump 3 must be 1-speed
Total of pump 1-low, O3 and Di1 must not exceed 20 FLA
Total of P3, CP, and Di2 must not exceed 20 FLA
* 
7
If A1 is used, Pump 4 must be 1-speed
Total of O3 and Di1 must not exceed 20 FLA
Total of P3, CP, and Di2 must not exceed 20 FLA
Total of P5, and B must not exceed 20 FLA
Total of P4, and A1 must not exceed 20 FLA
European Models

Table of Contents

Other manuals for Gecko Y Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gecko Y Series and is the answer not in the manual?

Gecko Y Series Specifications

General IconGeneral
BrandGecko
ModelY Series
CategorySpa Accessories
LanguageEnglish

Related product manuals