11
Parameter Screen Options Description
Pump 1 config�
Single speed = 1
Double speed = 2
*Pump1 and Pump3 = 3
Pump 1 configuration
*Offered on certain models only�
Pump 2 config�
Not installed = 0
Single speed = 1
Double speed = 2
Pump 2 configuration
Blower config�
Not installed = 0
Installed = 1
Blower configuration
Circ� Pump config�
Not installed = 0
Installed = 1
Activated = 2
Circulation pump configuration
Ozonator config�
Not installed = 0
Installed = 1
Activated = 2
Ozone generator configuration
Ozonator pump
Circulation pump = 0
Pump1 = 1
Pump associated with the ozone generator
Ozonator type
Standard = 0
Timed = 1
Ozone generator type
Heater pump
Circulation pump = 0
Pump1 = 1
Pump associated with the heater
Filter config�
Purge only = 0
With circ� Pump = 1
With Pump 1 low speed = 2
Configuration of the filtration cycle
Temp� units
°F = 0
°C = 1
Displayed temperature unit
Clock format
No time displayed = 0
AM/PM mode = 1
Mode 24H = 2
Clock display mode
Pump1 high speed
Current
1 to 20 amps (10) Current of pump 1 high speed
Pump1 low speed
Current
1 to 15 amps (4) Current of pump 1 low speed
Pump2 high speed
Current
1 to 15 amps (10) Current of pump 2 high speed
Pompe2 low speed
Current
1 to 15 amps (4) Current of pump 2 low speed
Blower current
1 to 10 amps (5) Current of blower
Circ� Pump current
1 to 5 amps (2) Current of circulation pump
Direct current
0 to 5 amps (1) Current of the direct output
Heater current
4 to 17 amps (17) Heater current
Minimum input current
10 to 20 amps Minimum input current (breaker size)
Input current
15 to 48
(on UL/CSA systems) (48)
15 to 32 (on CE systems) (32)
Available household current (Maximum input current)
* Offered on certain models only.
Field programming options for control systems
Table 3 - in.xe (older versions only)