3
Lamp test
All segments and LEDs
light up�
Software revision Low-level selected
Low-level selected from the
low-level menu�
Software number
8.8.8
Display sequence at start up (every parameter is displayed for 2 seconds)
IMPORTANT Please read the following before starting the device.
Verify that all accessories are linked to the ground lug and connected to the to the
control system.
A minimum flow of 68 LPM (18 GPM) is required. Make sure that all valves are
open in the spa plumbing and that the water flow is sufficient between the main
pump and the water heater.
Turn on the breaker.
in.flo dry-fire protection
At start up, the in�flo’s detector verifies the water flow according to the following sequence:
The Pump 1 or the circulation pump runs for a period of 2 to 5 minutes�
The display will show “- - -“ during the flow verification� After this time, the system confirms if flow is adequate
or not�
If the flow is sufficient, the temperature of the water is displayed on the keypad screen� When the water has reached the
consigned temperature plus 0�45°C (0�8°F), the water heater turns off�
Power up and breaker setting