Geekpure RO4 Series system uses four stages of treatment to filter your water:
Stage 1 - Remove sand, dirt, sediment
Stage 2 - Remove chlorine, taste & odors, very fine particulates
Stage 3 - Reduce total dissolved minerals
Stage 4 - Polish water for refined taste
How Your System Works
Technical Data of Membrane
The system is compact and can be installed under the sink or another convenient place
close to the faucet. The closer the proximity to the faucet the better the system flow
rate.
Recommended Filter Change Schedule
Your filters require changing on a regular basis. Instructions to change them are on.
The schedule below is the minimum page 17 recommendation. Depending on your
water conditions the filters may need to be changed more often.
Disposable Filters
T33-PP
T33-CARBON
TW-1812-100G
RO5-COC10
Change Schedule
Every 6-12 months
Every 6-12 months
Every 15-24 months
Every 6-12 months
MEMBRANE
Type — TFC (Thin Film Composite)
Material — PA (Polyamide)
Charge — Negative
Configuration — Spiral-wound, Tapping
PERFORMANCE (NORMINAL)
Salt Rejection — 96%(minimum)
The stated performance is initial data taken after 30 minutes of opera-
tion based on the following conditions.