Before You Start
Your system contains filters which must be replaced periodically for proper
operation. (Refer to Filter Change Schedule on page 17.)
Read all steps and guides carefully before installing and using your RO system.
Follow all steps exactly to correctly install.
The system is designed to be used on potable water supplies only. If water is
non-potable, additional pretreatment will be required.
Concentration — 250ppm NaCl
Pressure — 60psig
Temperature — 77°F (25°C)
Recovery —15%
pH Range — 6.5 ~ 7.0
Note:Due to different temperature, different water pressure and feed water
quality, the product water capacity and pure water quality (TDS) is different.
That is the reason why we feel lower pure water capacity in the winter, but
higher in the summer. Please refer following diagram:
OPERATING LIMITS
Max.Operating Pressure — 125psi (0.86Mpa)
Max.Feed Flow Rate — 2gpm (0.45m3/hr)
Max.Feed Water TDS — 1000 ppm (if 2000 ppm, it is available,but out of
warranty, life time will be shorter.)
Max. Operating Temperature — 110°F (45°C)
Min.Operating Temperature — 40°F(5°C)
pH -3.0 ~10.0
Chlorine Concentration — <0.1ppm
Hardness <5GPG