Guidelines for component placement are as follows:
Faucet should be placed near the sink where drinking/cooking water is normally
required. A 2" flat surface is required to mount the faucet if an existing hole for a
second faucet is not available.The thickness of the mounting surface should not
exceed 1-1/4" on the vertical or horizontal tailpiece. Refer to Figure 1.
Storage tank may be placed where it is convenient, within ten feet of the faucet.
Under the sink or in a nearby cabinet are excellent choices. If tank is located further
than ten feet from the faucet, use 1/2" tubing to reduce pressure drop. Full tanks may
weigh more than thirty pounds, so a sturdy shelf is required.
RO unit may be mounted on either side of the sink, in a cabinet or heated basement,
with nearby access to a potable, cold line and a drain.
NOTE: All components and tubing should be located in an area not exposed to
freezing temperatures or direct sunlight.
In the cabinet On the cabinetMounted on the wall
Feed water connection is accomplished with a feed water adaptor. Locate this assembly
as close to the R/O unit as possible. Connect to a potable, cold water supply line only.
NOTE: Softened water is preferred since it will extend the life of your R/O membrane.
Drain connection is accomplished using a waste water saddle valve which is designed to
fit around a standard 1-1/2" OD drain pipe. The drain saddle valve should always be
installed above (before) the drain trap and on the vertical or horizontal tailpiece. Refer to
Figure 2.
Figure 1