Positions:
Position 1:
Pulse dialling. The R is grounded. This option
can be used only within the UK in very special
cases.
Position 2:
Pulse dialling. The R is set according to the
determined adjustment (see «Time Break Recall
Setting for R Function» p.9).
Position 3:
Tone dialling. The R is set according to the
determined adjustment (see «Time Break Recall
Setting for R Function» p.9).
If you are using your CL1100 with a hearing aid, set
your hearing aid to “T” position.
4 -TIME BREAK RECALL SWITCH (300/100)
Check the Time Break Recall setting of your
CL1100. For the UK the Time Break Recall
should be set to 100 mS. It can be switched to
300 mS for other locations or PBX’s.