4-30
01- 01
V/f Maximum voltage
Range
200:170.0~264.0V
400:323.0~528.0V
01- 02
Maximum Frequency (base frequency)
Range
0.2 ~ 599.00
Hz
01- 03
Maximum Frequency Voltage Ratio
Range
0.0 ~ 100.0
%
01- 04
Medium Frequency 2
Range
0.1 ~ 599.00
Hz
01- 05
Medium Frequency Voltage Ratio 2
Range
0.0 ~ 100.0
%
01- 06
Medium Frequency 1
Range
0.1 ~ 599.00
Hz
01- 07
Medium Frequency Voltage Ratio 1
Range
0.0 ~ 100.0
%
01- 08
Minimum Frequency
Range
0.1 ~ 599.00
Hz
01- 09
Minimum Frequency Voltage Ratio
Range
0.0 ~ 100.0
%
Max output frequency depends on parameter 01-00 , for 01-00=7It can be set by parameter
01-02.
For 01-00 ≠7, the maximum output frequency depends on parameter 00-12, frequency
upper limit.
01-10
Volts/Hz Curve Modification (Torque Boost)
Range
0 ~ 10.0
%
Inverter output V / F curve settings for points B, C can be adjusted by parameter 01-10 to
improve the output torque.
Calculation of B, C point voltage: B point voltage = Xb × maximum output voltage, C point
voltage = Xc × maximum output voltage (Xb, Xc see 01-00). When 01-10 = 0, the torque
improvement is disabled.